Clearing a Backup-Failure Alarm

Clearing a Backup-Failure Alarm

If you use Backup Programming—Automatic (#123) and the automatic backup fails, a Backup-Failure Alarm message appears (instead of the default day/date/time message) on the top line of the telephone display at idle extensions 10 and 11.

After correcting the problem that caused the failure, you can clear the Backup-Failure Alarm using the following procedure. (See Figure 2-2on page 2-19for the location of special programming buttons such as sand

eon system phones.)

1.Press f00ss#1 23.

The current setting is displayed.

2. Press 3to choose Option 3, “Backup Alarm Cleared.”

NOTE:

You cannot use Dor din this procedure to choose Option 3.

NOTE:

If an ASA/DXD or PARTNER Voice Mail PC card is in use, perform Backup Programming—Manual (#124) as described in Chapter 5. Deactivate automatic backup to prevent this from re-occurring.

3. Exit programming mode.

NOTE:

Using Option 3 to clear a Backup-Failure Alarm does not change the setting for Backup Programming—Automatic (#123) . It remains either Active or Not Active.