Lucent Technologies 518-458-100 manual Problems with System Restore

Models: 518-458-100

1 407
Download 407 pages 55.58 Kb
Page 359
Image 359

Troubleshooting

Problems with System Restore

Display Shows “Insert Card” in

System Programming Mode

Possible Cause: The system did not detect a valid Backup/Restore PC Card when you tried to do a restore using Restore Programming (#125).

What to do: Power down the system, insert a valid Backup/Restore PC Card in the PC Card Slot of the PARTNER Endeavor processor module, and reapply power to the system. Restart the procedure.

Display Shows “Bad File” in

System Programming Mode

Possible Cause: You attempted a restore and the file was corrupted.

What to do: Try Restore Programming (#125) again with a different backup file. Remember to power down the system before you insert or remove Backup/Restore PC Cards.

Display Shows “Empty File” in

System Programming Mode

Possible Cause: You selected a file named AUTO.****** or MAN.****** for the restore. The file is empty; no backups have been stored in it yet.

What to do: Try Restore Programming (#125) again using a file created during a backup procedure. Remember to power down the system before you insert or remove Backup/Restore PC Cards.

Display Shows “Incompat Versions” in

System Programming Mode

Possible Cause: You attempted to restore a file that was created with an incompatible software release.

What to do: Try Restore Programming (#125) again using a backup file that was created with the current software release.

6-28

Page 359
Image 359
Lucent Technologies 518-458-100 manual Problems with System Restore, Display Shows Bad File System Programming Mode