Lucent Technologies 518-458-100 manual Doorphone Alert Extensions #606, Valid Entries

Models: 518-458-100

1 407
Download 407 pages 55.58 Kb
Page 190
Image 190

Doorphone Alert Extensions (#606)

Doorphone Alert Extensions (#606)

Description

This System Programming procedure identifies extensions that are signaled when a doorphone button is pressed. When a person uses the doorphone, it signals all alert extensions at the same time. If the alert extension is a system phone, the call signals with a unique ding-dongsound to distinguish it from other calls.

Additionally, if you have two doorphones, they signal with different tones so you can distinguish between them.

Related Features

You must use Doorphone Extensions (#604 and #605) to identify the extensions to which doorphones are connected.

If Do Not Disturb is active at a doorphone alert extension, the person at the doorphone hears signaling, but the alert extension is not signaled.

Considerations

You cannot bridge two doorphones together.

Valid Entries

1 = Not an Alert Extension

2 = Doorphone 1 Alert Extension

3 = Doorphone 2 Alert Extension

4 = Doorphones 1 and 2 Alert Extension

Programming

(See Figure 2-2on page 2-19for the location of special programming buttons such as sand eon system phones.)

To identify doorphone alert extensions:

1.Press f00ss#60 6at extension 10.

2.Enter the first alert system extension number. For example, to identify extension 10, press 10.

3.To change the alert status, press Duntil the appropriate value displays.

4.To identify another alert extension, press nor puntil the extension number shows on the display. Then repeat Step 3.

5.Select another procedure or exit programming mode.