Lucent Technologies 518-458-100 manual Rotary Dialing Timeout #108, 185

Models: 518-458-100

1 407
Download 407 pages 55.58 Kb
Page 284
Image 284

Rotary Dialing Timeout (#108)

Rotary Dialing Timeout (#108)

Description

This System Programming procedure changes the length of the Rotary Dialing Timeout. You may need to change the length of the timeout if you have any rotary lines and you are having trouble calling out on standard touch-tone phones. For example, if users dial slowly and calls are not completed or are connected to wrong numbers, lengthen the timeout.

Related Features

Use this procedure only if the Dial Mode (#201) for at least one outside line in the system is set to rotary.

Considerations

Do not change this setting unless the system is experiencing problems.

Valid Entries

1 = 4 seconds

2 = 8 seconds

3 = 12 seconds

Programming

(See Figure 2-2on page 2-19for the location of special programming buttons such as sand eon system phones.)

To change the length of the Rotary Dialing Timeout:

1.Press f00ss#10 8at extension 10 or 11.

2.Press Duntil the appropriate value displays.

3.Select another procedure or exit programming mode.

5-185

Page 284
Image 284
Lucent Technologies 518-458-100 manual Rotary Dialing Timeout #108, 185