Lucent Technologies 518-458-100 manual Using the Recall Feature Has No Effect

Models: 518-458-100

1 407
Download 407 pages 55.58 Kb
Page 351
Image 351

Troubleshooting

Automatically Dialed Calls Beginning with

Star Codes Are Misrouted

Possible Cause: The Star Code Dial Delay setting is not inserting a long enough pause, allowing a portion of the phone number to be dialed before the second dial tone from the Central Office is established.

What to do: Use Star Code Dial Delay (#410) to increase the Star Code Dial Delay setting.

Using the Recall Feature Has No Effect

Possible Cause: Recall Timer Duration setting is too short.

What to do: Increase the Recall Timer Duration (#107) by 100 milliseconds.

If the Recall feature works, the problem is solved.

If the Recall feature still does not work, continue increasing the Recall Timer Duration by increments of 100 milliseconds until the problem is solved.

Using the Recall Feature Disconnects Call

This problem applies when the system is installed behind a PBX or Centrex system or with the local phone company’s “Call Waiting” feature.

Possible Cause: Recall Timer Duration setting is too long.

What to do: Decrease the Recall Timer Duration (#107) by 100 milliseconds.

If the Recall feature works properly, the problem is solved.

If the Recall feature still disconnects calls, continue decreasing the Recall Timer Duration by increments of 100 milliseconds until the problem is solved.

6-20

Page 351
Image 351
Lucent Technologies 518-458-100 manual Using the Recall Feature Has No Effect, Using the Recall Feature Disconnects Call