Lucent Technologies 518-458-100 manual Problems with ASA/DXD Cards

Models: 518-458-100

1 407
Download 407 pages 55.58 Kb
Page 354
Image 354

Problems with ASA/DXD Cards

Problems with ASA/DXD Cards

An ASA/DXD Missing Card Error Message Appears

Possible Cause: You are attempting to record an Automatic System Answer message (I891) or a Direct Extension Dial (DXD) message (I892) and an ASA/DXD PC card is not installed in the processor module.

What to do: To clear the message, at extensions 10 and 11, program an Automatic System Answer button (#111) if you used I891 to attempt to record the greeting or a Direct Extension Dial button (#112) if you used I892 to attempt to record the greeting. Press the programmed button to turn the feature on then press the programmed button to turn it off again. After you turn the feature off, the error message should be cleared and you can remove the button assignment using (#111) or #112).

6-23

Page 354
Image 354
Lucent Technologies 518-458-100 manual Problems with ASA/DXD Cards, An ASA/DXD Missing Card Error Message Appears