Lincoln Electric IM557 manual Grounding Lead Protector, Explanation of Prompting Error Messages

Models: IM557

1 56
Download 56 pages 58.77 Kb
Page 29
Image 29

B-11

OPERATION

B-11

 

 

 

Grounding Lead Protector

The frame of the Synergic 7 wire feeder is grounded to the frame of the power source by a lead in the con- trol cable. An overload protector prevents welding current from damaging this lead if the electrode circuit touches the wire feeder frame while the electrode is electrically hot.

If such a grounding lead fault occurs, the wire feeder display will show "GLP", and the trigger circuit will be disabled. To reset the circuit, release the trigger, make sure that the electrode is not touching the wire feeder frame, and then either press any key on the keypad or close the trigger. When the GLP circuit is reset, the "GLP" display is removed and the wire feed- er is returned to normal operating mode.

Explanation of Prompting and

Error Messages

Display

Prompt or Error

HI

Indicates arc voltage is above 80V DC.

---Indicates selected Run-In speed will be the same as the weld speed. To enter a different Run-In speed simply press the increase arrow key with Run-In selected.

HXX

Indicates wire feed overload. XX indicates

 

time remaining in seconds before unit resets

 

automatically. See sections on Routine

 

Maintenance, Periodic Maintenance, and

 

Troubleshooting Guide Problem 24.

EP

Indicates problem in EPROM assembly. See

 

Troubleshooting Guide Problem 24.

uP

Indicates problem in microprocessor RAM.

 

See Troubleshooting Guide Problem 24.

EXX

Indicates various system problems. XX will

 

be a number from 01 to 10. Turn off power to

 

feeder. Wait 5 seconds. Turn power back on.

 

If error persists, see Troubleshooting Guide

 

Problem 24. If error does not reoccur, be

 

sure to check all wire feed speed, accelera-

 

tion, and timer settings before you proceed.

Er

EEPROM error. Usually occurs at power-up.

 

Indicates one or more of the recalled settings

 

is out of acceptable limits. Press any key to

 

return to normal operation. Be sure to check

 

all wire feed speed, acceleration, and timer

 

settings before you proceed.

GLP

Indicates that the Grounding Lead Protector

 

circuit was activated due to excessive current

 

flow into the wire feeder frame. When the

 

Grounding Lead Protector circuit is activated

 

the wire feeder is disabled, i.e. the trigger out-

 

put to the power source is opened up, the

 

motor is stopped, and the gas solenoid is

 

turned off. To resume normal operation,

 

release the trigger, make sure that the elec-

 

trode is not touching the wire feeder frame,

 

and then either press a key on the keypad or

 

close the trigger. See Problem 24 in the

 

Troubleshooting Guide.

SYNERGIC 7 & 7H

Page 29
Image 29
Lincoln Electric IM557 manual Grounding Lead Protector, Explanation of Prompting Error Messages