Lincoln Electric IM557 manual Safety Precautions, Electric Shock can kill

Models: IM557

1 56
Download 56 pages 58.77 Kb
Page 12
Image 12

A-5

INSTALLATION

A-5

 

 

 

INSTALLATION OF THE SYNERGIC 7 COMPONENTS

Safety Precautions

WARNING

ELECTRIC SHOCK can kill.

Do not touch electrically live parts such as output terminals or internal wiring.

When inching with gun trigger, electrode and drive mechanism are “hot” to work and ground and could remain energized several seconds after the gun trigger is released.

Turn OFF input power at welding power source before installation or changing drive roll and/or guide tubes.

Welding power source must be connected to system ground per the National Electrical Code or any applicable local codes.

Only qualified personnel should perform this installation.

Observe all additional Safety Guidelines detailed throughout this manual.

Attaching Wire Reel Stand

The mounting hardware for mounting the wire reel stand is included with the wire feeder. (Screws and washers are inserted in their respective mounting holes.) To connect:

1)Remove the three 3/8" (9.5 mm) hex head screws from the back of the wire feed unit.

2)Place the wire reel stand mounting bracket in posi- tion against the back of the wire feed unit.

3)Replace and tighten the screws. The long screw and plain washer go into the top hole.

SYNERGIC 7 & 7H

Page 12
Image 12
Lincoln Electric IM557 manual Safety Precautions, Electric Shock can kill