E-4

TROUBLESHOOTING

E-4

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

7. No control of wire feed.

a. Problem with serial communications.

a. If WFS and preset Volts/Trim parame-

 

 

ters on wire feeder display do not

 

 

match those on power source display,

 

 

see Problem 14.

 

b. Defective wire feed motor tach or

b. Measure voltage across pin 2 (+) of J3

 

control PC Board.

and pin 3 (-) of J3 on PC board with

 

 

motor running. If voltage is 1.5-3.5V

 

 

then replace control PC board (see

 

 

Procedure for Replacing PC Boards).

 

 

If not, then replace tachometer.

8. No wire feed, solenoid, or arc volt- a. Faulty gun or gun trigger switch.

a. Remove gun. Check continuity

age. LED display indicated

between trigger pins with trigger

Synergic 7 has input power.

closed. If no continuity repair or

 

replace gun.

b. Defective control PC board or

b. Remove gun. Check voltage across

gun connector.

trigger sockets on gun connector.

 

If voltage > ± 11 VDC then gun is

 

defective.

 

If voltage is < ± 11 VDC then check

 

the voltage across pin 2 (+) and pin 8

 

(-) of connector J1 on control PC

 

board.

 

If the voltage is still < ± 11 VDC then

 

replace control PC board. (See

 

Procedure for replacing PC boards).

 

Otherwise, either the gun connector or

 

wiring harness is faulty.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

SYNERGIC 7 & 7H

Page 38
Image 38