TROUBLESHOOTING

E-5

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

9. Wire feed motor runs and solenoid

a. Power source is defective.

a. If arc voltage is present when wire feeder is

 

turns on but no arc voltage pre-

 

connected to the other input receptacle (#1 or

 

sent.

 

#2) of power source then power source is

 

 

 

defective. Otherwise, select a stick procedure

 

 

 

on power source, connect a known good input

 

 

 

cable (see step b) to wire feeder #1 receptacle

 

 

 

of power source, and jumper across sockets C

 

 

 

and D of 8-socket input cable plug. If no arc

 

 

 

voltage is present (refer to display on power

 

 

 

source) then power source is defective.

 

 

b. Input cable is defective.

b. Disconnect input cable from power source and

 

 

 

wire feeder. Check continuity between socket

 

 

 

C of 8-socket plug and pin C of 14-pin plug of

 

 

 

the input cable, and between socket D of 8-

 

 

 

socket plug and pin D of 14-pin plug of the

 

 

 

input cable. Replace cable if no continuity.

 

 

c. Wiring harness or Control PC

c. Check continuity between pin C of 8-pin recep-

 

 

board is defective.

tacle and pin 7 of plug P1, and between pin D

 

 

 

of 8-pin receptacle and pin 6 of plug P1. If no

 

 

 

continuity then harness is faulty, otherwise

 

 

 

replace Control PC board. (See procedure for

 

 

 

replacing PC boards.)

 

 

 

 

 

10. Speed does not change when

a. Run-in and weld speeds are set

a. Set run-in and weld speeds to desired set-

 

weld current flows.

to the same value or run-in is set

tings.

 

 

to ---.

 

 

 

 

b. Power Source may be defective

b. Make sure that parameters on power source

 

 

or there may be a problem with

display, such as WFS, match those on wire

 

 

the Serial communications.

feeder display. If not, refer to Problem 14.

 

 

 

Otherwise, replace control PC board. (See

 

 

 

procedure for replacing PC boards.)

 

 

 

 

11. Voltmeter does not function or

a. Electrode sensing lead or connec-

a. Check continuity from brass block on wire

 

read properly when arc voltage is

tions may be intermittent.

feeder to pin F of 8-pin control cable recepta-

 

present.

 

cle on wire feeder. If there is no continuity,

 

 

 

repair faulty connection.

 

 

b. Serial communication problem.

b. Make sure that parameters on power source

 

 

 

display, such as WFS, match those on wire

 

 

 

feeder display. If not, refer to Problem 14.

 

 

 

Otherwise, replace Control PC board. (See

 

 

 

procedure for replacing PC boards.)

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.