Lucent Technologies 518-458-100 manual Direct Extension Dial Delay #112, Description

Models: 518-458-100

1 407
Download 407 pages 55.58 Kb
Page 170
Image 170

Direct Extension Dial Delay (#112)

Direct Extension Dial Delay (#112)

Description

This System Programming procedure specifies the number of times (0–9) an incoming call should ring before it is answered by the Direct Extension Dial feature.

Related Features

Direct Extension Dial affects incoming calls only on lines identified using Direct Extension Dial Lines (#205).

You must program a button on the system display phone at extension 10 to turn Direct Extension Dial on and off. Use Direct Extension Dial Button (#113) to program the button.

You must use Direct Extension Dial Record/Playback to record a message to prompt callers to dial an extension number or Hunt Group number after the system answers an outside call.

If you use Caller ID, make sure Direct Extension Dial Delay is set to 2 rings or more to ensure that Caller ID information is captured.

Considerations

The Automatic System/Direct Extension Dial PC card is purchased separately and must be installed. If the PC Card has not been installed, see the PARTNER PC Card Installation Instructions.

Use the Direct Extension Dial Record/Playback feature to record a message before using Direct Extension Dial since there is no default message.

This feature works independently of Line Ringing, which determines how an outside call rings at the extension—immediately, after a 20 second delay, or not at all. Direct Extension Dial Delay specifies the number of rings a caller hears before the system answers the call.

Valid Entries

0–9 (0 rings = answered immediately)

2

Programming

(See Figure 2-2on page 2-19for the location of special programming buttons such as sand eon system phones.)

To change the number of times an incoming call rings at extension 10 before the system answers it:

1.Press f00ss#11 2.

2.To change the number of rings, press Duntil the appropriate value

displays.

3. Select another procedure or exit programming mode.

5-71