Outgoing Call Restriction (#401)

Valid Entries

1 = No Restriction (can make toll, local, and intercom calls) 2 = Inside (intercom) Only

3 = Local (intercom and local) Only

Programming

(See Figure 2-2on page 2-19for the location of special programming buttons such as sand eon system phones.)

To identify the types of outgoing calls that can be made on all lines at an extension:

1.Press f00ss#40 1at extension 10 or 11.

2.At the Extension: prompt, enter the number of the extension to be programmed. For example, to select extension 30, press 30.

3.To change the type of call restriction, press Duntil the appropriate value displays.

4.To program another extension, press nor puntil the extension number shows on the display. Repeat Step 3.

5.Select another procedure or exit programming mode.

5-161

Page 260
Image 260
Lucent Technologies 518-458-100 manual Valid Entries, 161