If the sensor is disconnected or short-circuited, the heating system is turned off. Test your sensor according to the following resistance table:

Sensor

Temp (˚C)

Temp (˚F)

Value (ohm)

–10

–14

64000

0

32

38000

 

 

 

10

50

23300

 

 

 

20

68

14800

 

 

 

30

86

9700

 

 

 

Error Codes

E0: Internal error. The thermostat must be replaced.

E2: External sensor short-circuited or disconnected.

Warmzone

2056 South 1100 East Salt Lake City, UT 84106 Tel (888) 488-9276 Fax (801) 326-5199 info@warmzone.com

www.warmzone.com

Important: All information, including illustrations, is believed to be reliable. Users, however, should independently evaluate the suitability of each product for their particular application. Tyco Thermal Controls makes no warranties as to the accuracy or completeness of the information, and disclaims any liability regarding its use. Tyco Thermal Controls' only obligations are those in the Tyco Thermal Controls Standard Terms and Conditions of Sale for this product, and in no case will Tyco Thermal Controls or its distributors be liable for any incidental, indirect, or consequential damages arising from the sale, resale, use, or misuse of the product. Speci￿cations are subject to change without notice. In addition, Tyco Thermal Controls reserves the right to make changes—without noti￿cation to Buyer—to processing or materials that do not a￿ect compliance with any applica- ble speci￿cation.

Page 6
Image 6
Tyco QuickStatTM specifications Sensor Testing, Error Codes, Warmzone