Specifications
Approvals
| C | US E157297 |
|
|
| LISTED |
|
|
| 2D03 |
|
|
|
| |
Technical Data |
| ||
|
|
| |
| Supply Voltage | 120/240 V ±15%, 50/60 Hz | |
| Maximum switching current | 16 A | |
|
|
| |
| Wiring | 12 AWG to 22 AWG | |
|
|
| |
| GFCI | Class A (5 mA trip level) | |
|
|
| |
| Temperature control range | 40 to 104˚F (5 to 40°C) | |
| Ambient temperature range |
| |
|
|
|
|
|
| Thermostat | 32 to 104˚F (0 to 40°C) |
|
|
|
|
|
| GFCI |
QuickStat™ Thermostat Installation & Operation Manual
General Information
Use of this Manual
This manual covers the installation and operation of the Raychem® QuickStat™ thermostat and must be used with the following document:
•QuickNet™ System Installation Manual (H57704)
Important: For the Tyco Thermal Controls warranty and agency approvals to apply, the instructions included in this manual and product packages must be followed.
Features
QuickStat is an electronic thermostat that must be used with the Raychem QuickNet floor warming mats.
QuickStat provides the following features:
•Includes an integrated Class A,
•Operates at 120/240 V 50/60 Hz.
•Switches on your heating system at predetermined times on different days of the week.
•Offers 4 periods (called events) each day that you can set at different temperatures.
•Comes with a preprogrammed schedule that is suitable for most installations. However, you can customize this program any time you wish.
•Allows you to reset the thermostat to factory settings.
•Changes the start time of a heating period automatically so that the desired temperature is reached at the time that you set.
•Controls the temperature of the floor through a temperature sensor that is placed in the floor construction.
Kit contents
A | 1 | QuickStat thermostat |
|
B | 2 | Mounting screws |
|
|
|
|
|
C | 1 | Floor temperature sensor 10 ft (3m) | A |
|
|
| |
|
|
|
B
C