Restore Programming (#125)

To initiate a restore:

1.If you have a Backup/Restore PC Card installed, skip to Step 2. If you do not have a PC Card installed, refer to the PARTNER PC Card Installation Instructions.

2.Press f00ss#125at extension 10 or 11.

The top line of the display shows Sys Set Restore.

If no PC Card is present in the PARTNER Endeavor processor module, the error message Insert Card is displayed. Install a new PC Card using the PARTNER PC Card Installation Instructions. Then repeat this procedure from Step 2. You must power down the system before removing or inserting a Backup/Restore PC Card.

You are prompted to choose the backup file you want to use for the restore. The bottom line of the display shows 1 MAN.mmddyy, where mmddyy represents the date of the manual backup on this card.

3.To change to the file created by an automatic backup, press 2.

The bottom line of the display shows 2 AUTO.mmddyy,where mmddyy represents the date of the automatic backup on this card.

NOTE:

If the date of the file (AUTO. mmddyy or MAN. mmddyy) indicates that this is not the file you intended to use, refer to the PARTNER PC Card Installation Instructions on how to install the Backup/Restore PC Card.

If the Backup/Restore PC Card is fresh from the factory, and no backups have been recorded on it yet, the filenames will be MAN.****** and AUTO.******, respectively. You cannot use these files for a restore; they will generate the error message Empty File after you press ein Step 4.

4.Press eto start the restore.

If the system detects an error before beginning the restore, the bottom line of the display shows an error message. (See Chapter 6, ‘‘Troubleshooting,’’ for more information about these messages.)

If the system does not detect an error, the restore begins.

If the restore is not successful, the display shows Restore Failed for two seconds. All calls that were in progress are disconnected and all of the system and telephone programming settings revert to the default settings. You are no longer in System Programming mode. Try the restore again.