VXI CT-400 user manual Voltage Peak Current IMP Dynamic Current IMD

Page 17

www.vxitech.com

POWER SPECIFICATIONS

POWER

Available

1630 W

 

 

 

Useable

1000 W

 

 

 

DC SUPPLY VOLTAGE

 

 

 

 

 

 

 

A total of 1000 W may be supplied to the modules with the following

 

maximum currents:

 

 

 

 

 

 

 

 

 

 

 

 

Voltage

 

Peak Current (IMP)

Dynamic Current (IMD)

 

 

 

+5 V

 

80 A

15 A

 

 

 

-5.2 V

 

60 A

10 A

 

 

 

-2 V

 

30 A

5 A

 

 

 

+12 V

 

17 A

3 A

 

 

 

-12 V

 

17 A

3 A

 

 

 

+24 V

 

12 A

4 A

 

 

 

-24 V

 

12 A

4 A

 

OUTPUT VOLTAGE

Voltage

Allowed Variation

 

 

 

 

+5 V

+0.25

V / -0.125

V

-5.2 V

-0.26 V / +0.125

V

-2 V

-0.10

V / +0.72

V

+12 V

+0.60 V / +0.36 V

-12 V

-0.60

V / +0.36

V

+24 V

+1.20 V / -0.72

V

-24 V

-1.20

V / +0.74

V

Ripple/Noise

DC Load

50mV

50mV

50mV

50mV

50mV

150mV

150mV

Induced Ripple

Noise

50mV

50mV

50mV

50mV

50mV

150mV

150mV

POWER INPUT

Input Voltage

100 V ac minimum, 240 V ac maximum

Nominal AC

Frequency

47 Hz - 63 Hz (47 Hz - 440 Hz with increased leakage current and reduced PFC)

Inrush Current

< 70 A (cold start or after 1 minute cool down)

Input Power

1000 W max

Input Leakage

< 1.24 MA @ 264 V ac, 53 Hz

Input Harmonics

Meets EN61000-3-2

Fuse

15 A, 250 V, slow blow

90 V– 250 V Operation

207 V– 250 V Operation

10 A, 250 V, slow blow

PERIODIC AND RANDOM DEVIATIONS

±24 V

150 mVP-P

All Others

50 mVP-P

AUXILIARY DC OUTPUTS

1.5 A each at all seven supply voltages (fused/self-healing)

POWER SUPPLY

UL, CSA, TUV approved

Shout circuit, over-voltage, reverse voltage and thermal shutdown protection

CT-400 Introduction

17

Image 17 Contents
CT-400 Chassis Page Table of Contents VXI Technology, Inc Limitation of Warranty WarrantyCertification Restricted Rights LegendSteve Mauga, QA Manager EMCTerms and Symbols General Safety InstructionsUse Proper Fuse Support Resources VXI Technology, Inc CT-400 Introduction Introduction IntroductionGeneral Description Power SuppliesBackplane Cooling Feature Replaceable power supply unit CT-400 Mainframe FeaturesFront Panel Voltage Indicators Voltage Indicator LedsPIN Signal Description Rear Panel Monitor / Control ConnectorMttr CT-400 SpecificationsMtbf Voltage Peak Current IMP Dynamic Current IMD TOP View Rear View CT-400 Options Options 100 & 106 Mounting FLANGES/HANDLES & 2U Cable Tray Option 106 2U Cable Tray Rear View VXI Technology, Inc Option 104 Hinged Custom Front Panel VXI Technology, Inc CT-400 Introduction Power Requirements InstallationAIR Flow Requirements Connecting the Mainframe to Earth GroundInstalling Blanking Panels Installing the Card Shield OptionOverview BENCH-TOPCT-400 USERack Mounting the CT-400 Option 100 Adjustable Rack Mount Flanges with HandlesOption 101 VXIplug&play VPP-* Rack Mount Kit Option 102 Rack Mount SlidesParts List Option 100 Adjustable Rack Mount Flanges with HandlesAssembly Procedure Required ToolsAdjustable Rack Mount Flange Installation Diagram Option 101 VXIPLUG&PLAY Rack Mount KIT Mounting Receptacle Supplied By Customer Option 102 Rack Mount Slides Rack Mount Slide Installation Diagram Option 103 Transparent Front Door Additional Rack Mount OptionsOption 104 Hinged Custom Front Panel Option 105/106 1U / 2U Cable TraysCT-400 Installation Option 103 Transparent Front Door Installation Procedure Transparent Door Installation Diagram Option 104 Hinged Custom Front Panel Installation Procedure Customizable Front Door Installation Diagram Option 105/106 1U/2U Cable Trays Installation Procedure 1U TOP and 2U Bottom Cable Tray Installation Diagrams Installation Procedure Installation of VXI ModulesDisconnecting the Mainframe VXI Technology, Inc CT-400 Installation Operation Remote Power ControlCT-400 Monitor Board Connector J210 CT-400 Monitor Board SignalsConnector J211 Service Information Cleaning the Power Supply Fan Filter Cleaning the AIR FiltersCleaning the Module Fan Filter Power Supply Replacement Procedure VXI Technology, Inc CT-400 Index Page Index