6.Tighten the captive retainer screw to ensure the Media Converter Module is locked in place.

7.Remove the dust cap from the fiber connector and connect the fiber and copper cables.

Removing Media Converter Modules

1.Loosen the captive retainer screw on the front of the Media Converter Module and gently pull the Media Converter Module out.

2.If not inserting a replacement, cover the opening slot with a face plate and secure the screw.

Installing the SFP Fiber Module

1.C-1110-SFP and CM-1110-SFP require an SFP fiber module. Locate appropriate fiber module and insert into opening.

2.Ensure the SFP module is properly seated.

3.SFP module may be inserted before or after the Media Converter module is inserted into the chassis.

4.Proceed with cable connections.

Installing the Duplex Fiber Cable

1.Locate a 1000Base-X compliant duplex (2 strands) fiber cable with appropriate connectors.

2.Connect the fiber cables from the Media Converter to the other Media Converter/switch/fiber device ensuring that the RX and TX are reversed (crossed) at the opposite end.

Perle 10/100/1000 Media Converter Module – Instal lation Guide 11

Image 11
Contents CM-1110-SFP Managed Module Installation GuideXxxxx CM-1110-XXXXX Managed Module 1110-SFPOverview Mode Distance WavelengthSFP Auto-MDIX Jumper InstallationDip Switches Auto-Config Jumper CM-1110 onlySwitch Position Mode Auto Negotiation copper SwitchLink Mode Switch Fiber Fault Alert Switch Duplex copper Switch Fiber Negotiation Switch Speed copper SwitchLoopback Switch Installing or Replacing Media Converter ModulesRemoving Media Converter Modules Installing the SFP Fiber ModuleInstalling the Duplex Fiber Cable Installing the Copper Cable Installing the Simplex Fiber CableStatus LED OperationPause Ieee 802.3xy Other FeaturesError Recovery Auto-MDIXNo connectivity TroubleshootingGeneral Fiber Optic Specifications Technical SpecificationsEthernet Copper Cabling Requirements Fiber Cabling RequirementsCompliance Information EN 55022, Class a EN 55024, Class a Laser Safety IECCopyright Warranty / Registration