Perle Systems CM-1000MM-XXXXXX Remote Loopback Fiber 1 Switch, Remote Loopback Fiber 2 Switch

Page 8

Remote Loopback Fiber 1 (Switch 4)

Switch Position

Mode

 

 

Up (default)

Disabled

 

 

Down

Enabled

 

 

Disabled: The loopback feature is disabled. This is the normal position for regular operation. The switch must be set to this position in order for data to pass through the Media Converter Module.

Enabled: This is a test mode. All data received on the receive (RX) fiber connection is looped back to the transmit (TX) fiber connection.

Note: Only one fiber interface can be in loopback at a time.

Remote Loopback Fiber 2 (Switch 5

Switch Position

Mode

 

 

Up (default)

Disabled

 

 

Down

Enabled

 

 

Disabled: The loopback feature is disabled. This is the normal position for regular operation. The switch must be set to this position in order for data to pass through the Media Converter Module.

Enabled: This is a test mode. All data received on the receive (RX) fiber connection is looped back to the transmit (TX) fiber connection.

Note: Only one fiber interface can be in loopback at a time.

Gigabit Fiber to Fiber Media Converter Module – Installation Guide

8

Image 8
Contents 1000MM-XXXXXX Overview Fiber port 2 MM2/SM2TX/RX Installation Auto-Config Jumper CM-1000MM onlyFiber Negotiation Switch Switch Position ModeLink Mode Switch Fiber Fault Alert SwitchIllustration of the FFA Sequence of EventsRemote Loopback Fiber 1 Switch Remote Loopback Fiber 2 SwitchInstalling Media Converter Modules Installing the Duplex Fiber Cable Removing Media Convert ModulesInstalling the Simplex Fiber Cable Operation Status LEDTroubleshooting GeneralNo connectivity MethodFiber Optic Specifications Technical SpecificationsFiber Cabling Requirements EN 55022, Class a EN 55024, Class a Laser Safety IECCompliance Information Warranty / Registration Contacting Technical Support