Perle Systems CM-1000MM-XXXXXX, C-1000MM-XXXXXX Installation, Auto-Config Jumper CM-1000MM only

Page 4

Installation

The default switch settings (all switches in the UP position) will work for most installations. See the Operation section of this guide for more details.

The module comes equipped with a bank of DIP switches and jumpers for setting configuration

The default DIP switch settings (all switches in the UP position) and jumper setting will work for most installations.

The following steps are used to configure the Perle Gigabit Fiber to Fiber Media Converter Module:

1.Set the Auto-Config jumper. (CM-1000MM only) (optional)

2.Set the DIP switch settings (optional).

3.Insert the Media Converter Module into the chassis.

4.Connect the fiber cables.

Auto-Config Jumper (CM-1000MM only)

The Auto-Config jumper is J5.

Refer to the diagram below for labelling.

Auto (Pin 2 and Pin 3 are strapped): When set to Auto the module will, at power-up, check its internal flash memory to see if configuration information has been downloaded to it from a management module. If so, it will use this as its running configuration. If there is no configuration in flash it will read the settings of the DIP switches and use those as its running configuration.

SW: (Pin 1 and Pin 2 are strapped): When set to SW (Switch), the module will, at power-up, read the settings of the DIP Switches and use those as it running configuration. It will ignore any configuration information in its flash memory.

NOTE: The default jumper setting is Auto

Gigabit Fiber to Fiber Media Converter Module – Installation Guide

4

Image 4
Contents 1000MM-XXXXXX Overview Fiber port 2 MM2/SM2TX/RX Installation Auto-Config Jumper CM-1000MM onlyFiber Negotiation Switch Switch Position ModeLink Mode Switch Fiber Fault Alert SwitchIllustration of the FFA Sequence of EventsRemote Loopback Fiber 1 Switch Remote Loopback Fiber 2 SwitchInstalling Media Converter Modules Installing the Duplex Fiber Cable Removing Media Convert ModulesInstalling the Simplex Fiber Cable Operation Status LEDTroubleshooting GeneralNo connectivity MethodFiber Optic Specifications Technical SpecificationsFiber Cabling Requirements Compliance Information Laser Safety IECEN 55022, Class a EN 55024, Class a Warranty / Registration Contacting Technical Support