Functional Specifications

 

Standard Range

 

 

High Output Range

Inputs

4-20 mA

 

 

 

 

 

Outputs

 

 

 

 

 

 

psig

1-17

3-15

3-27

6-30

2- 60

2-100

(BAR)

(0.07-1.2)

(0.2-1.0)

(0.2-1.8)

(0.4-2.0)

(0.14-4.0)

(0.14-6.9)

 

 

 

 

 

 

 

Supply

 

 

 

 

 

 

Pressure

22-60

20-100

32-100

35-100

65-100

105-130

psig

(1.5-4.0)

(1.4-6.9)

(2.2-6.9)

(2.4-6.9)

(4.5-6.9)

(7.2-9.0)

(BAR)

 

 

 

 

 

 

 

 

 

 

 

 

 

Air Consumption

1.5 scfh (0.04 m3/hr) at

 

 

4.5 scfh (0.13 m3/hr) at

*Zero-based units have

 

 

mid range typical

 

 

mid range typical

slightly higher air consumption

 

 

 

 

 

 

 

 

 

 

 

 

 

Flow Capacity

4.5 scfm (7.6 m3/hr) at

 

 

20.0 scfm (34.0 m3/hr) at

 

25 psig (1.7 BAR) supply

 

130 psig (9.0 BAR) supply

 

12.0 scfm (20.0 m3/hr) at

 

 

 

 

100 psig (7.0 BAR) supply

 

 

 

Temperature Limits

Operating: -40º to +160º F (-40º to +71º C)

 

 

 

Storage:

-40º to +200º F (-40º to +93º C)

 

 

Loop Load,

 

 

 

 

 

 

I/P Transducer

9.5 VDC @ 20 mA

 

 

 

 

Performance Specifications

Accuracy, Hysteresis

 

and Repeatability

±0.10% of span guaranteed

Deadband

0.02% of span

Position Effect

No measurable effect

Vibration Effect

Less than ±1.0% of span under the following conditions:

 

5-15Hz @ 0.8 inches constant displacement 15-500Hz @ 10g s

Supply Pressure Effect

No measurable effect

Temperature Effect

±0.045%/F (0.07%/C) of span

Reverse Polarity Effect

No damage occurs from reversal of normal supply current (4-20mA)

 

or from misapplication of up to 60mA

RFI/EMI Effect

Pending

Physical Specifications

Port Sizes

Pneumatic: 1/4” NPT

Media

Clean, dry, oil-free air-filtered to 40 micron

Mounting

Wall, panel, 2” pipe, or DIN rail (optional)

Materials

Housing: Chromate-treated aluminum with baked paint, NEMA 4X (IP65)

 

Elastomers: Buna-N

 

Trim: Stainless steel; brass; zinc-plated steel

Weight

13.0 oz. (0.4 kg)

 

 

Page 2

Image 5
Contents User’s Guide Servicing North America WARRANTY/DISCLAIMER Contents Functional Specifications SpecificationsPerformance Specifications Physical SpecificationsMounting DescriptionPrinciple of Operation Electrical Connections Pneumatic ConnectionsIntrinsically Safe Suitable for Direct Acting Calibration OperationCalibration Split Range Reverse Acting CalibrationTroubleshooting Maintenance and RepairsCleaning PrecautionsTemperature