3-2. Convergence
Preparation:
4.If the V.STAT magnet is moved in the direction of the (a) and (b) arrows, the Red, Green and Blue points move as
indicated below.
•Before starting this adjustment, adjust the focus, horizontal size and vertical size.
•Minimize the Brightness setting.
•Input a dot pattern from the pattern generator.
Horizontal and Vertical Static Convergence
Center dot | R |
G
B
R G B
V.STAT Vertical Static Magnet
HSTAT
convergence
control | C Board |
|
RV702 (H STAT)
H STAT Convergence (on mount side)
a
bB
a
G
a
bR
a
b
b
B
G
R
a
R G B
b
R G B
1.[Moving horizontally], adjust the H.STAT control so that the Red, Green and Blue points are on top of each other at the centre of the screen.
2.[Moving vertically], adjust the V.STAT magnet so that the Red, Green and Blue points are on top of each other at the centre of the screen.
3.If the H.STAT variable resistor is unable to bring the Red, Green and Blue points together at the centre of the screen, adjust the horizontal convergence with the H.STAT variable resistor and the V.STAT magnet in the manner indicated below.
[In this case, the H.STAT variable resistor and the V.STAT magnet influence each other].
•Tilt the V.STAT magnet and adjust the static convergence by opening or closing the V.STAT magnet.
b
a
a | b |
R | B |
GG
BR
Operation of the BMC (Hexapole) magnet.
R G B R G B R G B
RB R G BG
GRB
The movement of the magnets interact with each other and so the respective dot position should be monitored while carrying out this adjustment.
Use the H.STAT VR to adjust the Red, Green and Blue dots so that they coincide at the centre of the screen
(by moving the dots in the horizontal direction).
16