RCA AVC 776 appendix

Page 28

EVENT : when alarm input is triggered, VCR will record alarming channel more frequently. For example : VCR normal record method is 1-2-3-4-5-……-9. In

Event mode, when CH01 is triggered, the record method will become 1-2-1-3-1-4-1-5-…-9.

NORMAL : when external alarm is on, VCR will record normally as set up.

OFF : DMR will not record

3.9.5Press “ MENU ” : Confirm and exit the record setting

3.9.6Press “ MENU ”: Exit the channel setup

3.10MOTION DETECTION setup

3.10.1Press “ MENU “ to enter the menu set up, then “ Down” to CAMERA setup, Press “ENTER” twice to enter the Motion Detection Setup .

3.10.2Each screen displays the current camera picture overlaid with the motion targets (as Figure 1). You can push the button “ Left ” or “ Right ”, ” Up ” or “ Down ” to adjust motion detection in ON or OFF.

3.10.3The targets on each motion setup can be turned to ON or OFF individually by row. To set up targets, using the following front panel buttons:

3.10.3.1Press ‘ENTER” to confirm the channel

3.10.3.2Press “ENTER” to enter motion mode

3.10.3.3▲ Up -- moves the target cursor up one row at a time.

3.10.3.4▼ Down -- moves the target cursor down one row at a time.

3.10.3.5◄ Left -- moves the target cursor left one column at a time.

3.10.3.6► Right -- moves the target cursor right one column at a time.

3.10.3.7Press “ENTER” to turn the target cursor ON

Press “ENTER” again to turn the target cursor OFF

3.10.3.8Camera Select (1-15) -– toggles the corresponding target on the cursor line ON or OFF. (Figure 1) There are only 15 targets in a row, therefore; only Camera Selected (1-15) can be operated.

3.10.3.9Zoom – turns all targets in the current row ON or OFF. (Figure 1-2)

3.10.3.10PIP – turns all targets on the screen ON or OFF. (Figure 1-3)

3.10.4Press “ SLOW “ button to setup the Sensitivity list up to 255

Press “ REC “ button to setup the Sensitivity list down to 000

Sensitivity value is related to motion and brightness change.

Low value (as 001) means higher sensitivity on motion and brightness change. High value (as 255) means lower sensitivity on motion and brightness change. User can choose the suitable sensitivity value in different locations.

The default value is set on 032.

Note:

If Motion Detection is set, and to be activated, there will be 2 actions as followings:

1). Live video - the motion detected camera(s) will be scanned more frequently, if the Video set up for 16 cameras, the sequence to scan the cameras are from 1st, 2nd, 3rd... until 16th

28

Image 28
Contents Introduction Safety Warning FeaturesSpecifications Installation Connection Install HDD Front panel keypad OFFNtsc System IPS PAL System IPS17 16 15 14 Back panel connection CallAudio OUT R/L PIN 1. GND Ground PIN 2. Alarm InputMain PIN 4. Alarm Input PIN 3. Alarm InputPIN 5. Alarm Input PIN 13. External Alarm no PIN 14. PIN OFF PIN 15. Alarm InputPIN 16. Alarm Input PIN 17. Alarm InputMenu setup System setupPIN 21. PIN OFF PIN 22. Alarm Input PIN 25. External Alarm COMSearch Timer Record Camera System Event Time Display Y/M/D Motion Audible Alarm 30 MIN, AlwaysPage ALL Data in HDD will be Cleared are YOU SURE? no YES Search setup Last Record Full List Alarm List Motion List Time Search Show a listing of all motion detection triggered Timer setup Schedule Time-Lapse record mode setup Record setup BEST, HIGH, NORMAL, BasicDisplayed.SEARCH Find recorded list Motion Trigger Record Camera setup Title Dwell Alarm Record LOW EventMenu Page Motion Detection Setup Motion Detection Setup ALL EventPower on OperationRecording Camera Select SelectPiture in Picture PIP ZoomPlay Trouble shooting Problem RemedyCompatible HDD brands Manufacturer Model Capacity Rotation