VICON protocol (4800 or 9600 baud)

Function

Panasonic Procedure

Program preset 1 – 32

As normal – refer to Panasonic Manual

Goto preset 1 – 32

As normal – refer to Panasonic Manual

Display Menu

As normal – refer to Panasonic Manual

 

Use the Joystick to move the dome cursor and either

 

the joystick button or SET.

 

SET sends an AP command

 

ESC sends an AI command

 

AUX1 & AUX2 are also used within the Vicon menu.

TOUR 80 playback

PATROL

AUTOTOUR 88 playback

AUTOPAN

Ensure that the dome address matches the address that the Panasonic equipment is sending using the address switch on the dome base plate.

Supports 4800 and 9600 baud rates. Please select the baud rate required using SW1 as diagram on page 6.

With a Vicon Surveyor 2000 dome ensure the following switch settings are used.

VPS

DUPLEX

RS422

Data connection between PC8 and dome

PC8

Dome

TRA

COMM IN+

TRB

COMM IN-

Notes

Some notes that can help installation of the PC8 with a Panasonic matrix to a site with existing Vicon domes:

1.When star wiring a single dome from a PC8 output set the dome to RS422.

2.Daisy chaining multiple cameras from a PC8 output set the dome to RS485.

3.Some domes do not auto detect the baud rate on power up which will prevent control if the dome is not set to the same baud rate as the PC8. To force the dome to auto detect

a.power off dome

b.set dome to vicoax (Vicon up the coax instead of RS422/485 control)

c.power on dome then power off after 10 second

d.set dome to VPS and power on

4.If all else fails and you do can not control the dome just try swapping the data cable between TRA & TRB on the PC8 output. It is possible that the data cable may have a joint in a junction box between the PC8 and the dome.

Panasonic Protocol Converter Manual V10.2 5Mar 09

Page 12/16

Image 12
Contents Installation Guide PRE-INSTALLATION Checks and Safety Procedures Panasonic Protocol Converter Manual V10.2 5Mar 3/16 Technical Specification Power Requirements Introduction General Internal view showing switches V12 Software Switch details main Starcard PCB Function Panasonic Procedure VCL TP protocolPrivacy Zones Pelco P specific functionality Dennard protocol Vicon protocol 4800 or 9600 baud TRA Comm IN+ TRBBlank for your notes Panasonic Protocol Converter Manual V10.2 5Mar 14/16 Panasonic Protocol Converter Manual V10.2 5Mar 15/16 Other products in the Panasonic range