Panasonic PC8 manual VCL TP protocol, Function Panasonic Procedure

Page 8

VCL TP protocol

Function

Panasonic Procedure

Program preset 1 – 32

As normal

Goto preset 1 – 32

As normal

Enable Privacy zone 100 – 127

Program preset 64

 

Followed by goto preset 1 – 28 (1 = zone 100)

Disable Privacy zone 100 – 127

Program preset 63

 

Followed by goto preset 1 – 28 (1 = zone 100)

Define Preset Patrol – START

Program preset 62

 

Followed by 3 preset commands per preset position

 

PRESET NUMBER - GOTO PRESET 1-32

 

SPEED - GOTO PRESET 1-63, 64 = fastest

 

DWELL – GOTO PRESET 1-64 (x 2 seconds)

Define Preset Patrol – STOP

Program preset 61

Start Preset Patrol

AUTOPAN

Path 5 LEARN start

PATROL LEARN or Program preset 60

 

Use joystick to move dome around required path

Path 5 LEARN stop

PATROL STOP or Program preset 59

Path 5 PLAYBACK

PATROL PLAY

Preset positions

The unit supports 32 preset positions per dome. Use the standard Panasonic method to program a preset and also to goto preset.

Preset Tour 1

The dome’s preset tour 1 can be defined as follows

PROGRAM PRESET 62 : the converter is now waiting for 3 preset calls per position

GOTO PRESET 1-32 : this is the preset position that is being programmed

GOTO PRESET 1-64 : this is the speed, 1-63 are increasing speeds and 64 is maximum

GOTO PRESET 1-64 : this is the dwell in 2 seconds to stay at the preset position

PROGRAM PRESET 61 : this is the end of the tour definition

Example presets 1,2,8,16

PROGRAM PRESET 62 – start definition

GOTO PRESET 1 – preset position 1

GOTO PRESET 64 – maximum speed

GOTO PRESET 10 – 20 second dwell

GOTO PRESET 2 – preset position 2

GOTO PRESET 20 – slowish speed

GOTO PRESET 15 – 30 second dwell

GOTO PRESET 8 – preset position 8

GOTO PRESET 1 – very slow speed

GOTO PRESET 2 – 4 second dwell

GOTO PRESET 16 – preset position 16

GOTO PRESET 63 – fast speed

GOTO PRESET 1 – 2 second dwell

PROGRAM PRESET 61 – end definition

Panasonic Protocol Converter Manual V10.2 5Mar 09

Page 8/16

Image 8
Contents Installation Guide PRE-INSTALLATION Checks and Safety Procedures Panasonic Protocol Converter Manual V10.2 5Mar 3/16 Technical Specification Power Requirements Introduction General Internal view showing switches V12 Software Switch details main Starcard PCB Function Panasonic Procedure VCL TP protocolPrivacy Zones Pelco P specific functionality Dennard protocol Vicon protocol 4800 or 9600 baud TRA Comm IN+ TRBBlank for your notes Panasonic Protocol Converter Manual V10.2 5Mar 14/16 Panasonic Protocol Converter Manual V10.2 5Mar 15/16 Other products in the Panasonic range