VCL TP protocol
Function | Panasonic Procedure |
Program preset 1 – 32 | As normal |
Goto preset 1 – 32 | As normal |
Enable Privacy zone 100 – 127 | Program preset 64 |
| Followed by goto preset 1 – 28 (1 = zone 100) |
Disable Privacy zone 100 – 127 | Program preset 63 |
| Followed by goto preset 1 – 28 (1 = zone 100) |
Define Preset Patrol – START | Program preset 62 |
| Followed by 3 preset commands per preset position |
| PRESET NUMBER - GOTO PRESET |
| SPEED - GOTO PRESET |
| DWELL – GOTO PRESET |
Define Preset Patrol – STOP | Program preset 61 |
Start Preset Patrol | AUTOPAN |
Path 5 LEARN start | PATROL LEARN or Program preset 60 |
| Use joystick to move dome around required path |
Path 5 LEARN stop | PATROL STOP or Program preset 59 |
Path 5 PLAYBACK | PATROL PLAY |
Preset positions
The unit supports 32 preset positions per dome. Use the standard Panasonic method to program a preset and also to goto preset.
Preset Tour 1
The dome’s preset tour 1 can be defined as follows
PROGRAM PRESET 62 : the converter is now waiting for 3 preset calls per position
GOTO PRESET
GOTO PRESET
GOTO PRESET
PROGRAM PRESET 61 : this is the end of the tour definition
Example presets 1,2,8,16
PROGRAM PRESET 62 – start definition
GOTO PRESET 1 – preset position 1
GOTO PRESET 64 – maximum speed
GOTO PRESET 10 – 20 second dwell
GOTO PRESET 2 – preset position 2
GOTO PRESET 20 – slowish speed
GOTO PRESET 15 – 30 second dwell
GOTO PRESET 8 – preset position 8
GOTO PRESET 1 – very slow speed
GOTO PRESET 2 – 4 second dwell
GOTO PRESET 16 – preset position 16
GOTO PRESET 63 – fast speed
GOTO PRESET 1 – 2 second dwell
PROGRAM PRESET 61 – end definition
Panasonic Protocol Converter Manual V10.2 5Mar 09 | Page 8/16 |