Aluminum Electrolytic Capacitor
■ Typical failure modes and their factors |
|
|
|
|
|
| ||||
Faliure mode | Faliure mechanism (internal phenomenon) | Production factor | Application factor | |||||||
|
|
|
|
|
|
|
|
|
| Overvoltage applied |
Vent operates |
| Increase in | • | Increase in inter- | • |
|
| |||
|
| internal pressure |
| nal temperature |
|
|
| |||
|
|
|
|
|
|
|
|
| • | Excessive ripple current |
Capacitance |
| Reduced anode foil |
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| |||
reduction |
| capacitance |
|
|
|
|
|
|
| Reverse voltage applied |
|
|
|
|
|
|
|
| • | ||
|
|
|
|
|
|
|
|
| ||
• |
| • |
| • | • |
|
| • |
|
|
tan d increase |
| Reduced cathode |
|
|
|
|
|
| ||
|
| foil capacitance |
|
|
|
|
| • | Severe | |
|
|
|
|
|
|
|
|
|
| AC voltage applied |
|
|
|
|
|
|
|
| • | Defect of oxide film |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| • | • | Used for a high temperature |
|
| Deterioration of |
| • |
|
| • | Insufficient |
| |
|
| oxide film |
|
|
|
|
| electrolyte |
| |
|
|
|
|
|
|
|
|
| ||
Leakage current | • | • |
|
|
|
|
|
|
| Used for a long period of time |
increase |
|
|
|
|
|
|
|
|
| |
| Electrolyte evapora- |
|
|
|
|
|
| |||
|
|
|
| • |
| Metal particles |
| |||
|
| tion |
|
|
|
|
|
| ||
|
|
|
|
|
|
| in capacitor |
| ||
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| • | • |
| Stress applied to leads |
Short circuit |
| Insulation breakdown of film | • |
|
|
|
| |||
| or electrolytic paper |
|
|
| Burr(s) on foil leads |
| ||||
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
| Leads improperly |
|
|
|
|
|
|
|
|
|
| connected |
|
|
| Leads improperly connected |
| • |
| Mechanical stress |
| |||
Open | • | • |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Use of Halogenated solvent |
|
| Corrosion |
| Infiltration of Cl |
|
| • |
| ||
|
|
|
|
|
|
|
|
|
| Use of adhesive |
|
|
|
|
|
|
|
|
|
| Use of coating material |
Design, Specifications are subject to change without notice. Ask factory for technical specifications before purchase and/or use.
Whenever a doubt about safety arises from this product, please inform us immediately for technical consulation without fail.
– EE17 –