Options Adjustments
| Options | 3/3 |
|
| Slot power | Off | |
| Power On Screen Delay | Off | |
| V. lnstallation | Off | |
| Rotate | Off | |
| Serial Slot Select | Slot1 |
|
Item | Effect |
|
|
| Adjustments |
|
|
| Off |
| Auto | On |
|
|
|
| Off: | Power is not transmitted to the slot power. |
|
| |||
Slot Power | Auto: Power is transmitted to the slot power only when main power is on. |
| |||||
On: | Power is transmitted to the slot power when main power is on or in the standby state. |
| |||||
|
| ||||||
| Note: In some cases, power is transmitted to the slot power when main power is on or in the standby | ||||||
|
| state regardless of the slot power setting. |
|
| |||
|
|
|
|
|
|
|
|
| Off | 1 | 2 | 3.... | 30 |
|
|
| You can set the | to | |||||
| turn on the multiple displays that are set together, for example, on MULTI DISPLAY system. |
| |||||
| Set each display’s setting individually. |
|
| ||||
| Off: |
| The display will be turned on at the same time as | is pressed. |
| ||
| 1 to 30 (sec.): Set the |
|
| ||||
Power On | Notes: |
| After pressing | , the display will be powered on with time delay depending on this setting. | |||
|
|
|
|
|
| ||
Screen Delay | • During this function is working, the power indicator is blinking green. |
|
•This function also works when the power recovers from failure or after plugging off and in again the power cord.
After you unplug and plug the power cord in while the unit is in standby mode and also the power is being supplied to a terminal board, the unit will start supplying the power to the board with time delay according to the setting.
The power indicator lights up red first and it turns orange when the power starts being supplied to the board.
|
|
| Off: | Sets fan to the horizontal installation mode. | ||
V.Installation |
|
| On: | Sets fan to the vertical installation mode. | ||
Off | On | Notes: |
|
| ||
| • This functions when display is turned on. | |||||
|
|
| ||||
|
|
| • If the display is installed vertically, the power switch should be located at the bottom. | |||
|
|
|
|
| ||
Rotate |
|
| Off: | Does not rotate the image. | ||
Off | On On: | Rotates the image 180 degrees. | ||||
| ||||||
Serial Slot |
|
| Slot1 | Slot2 | Slot3 | |
|
| Selects the slot which communicates serial. | ||||
Select |
|
| ||||
|
| Note: The setting of an external command can be set only from the fixed serial terminal. (see page 11) | ||||
|
|
|
Normalization
When both main unit buttons and remote control are disabled due to the “Button lock”, “Remocon User level” or “Remote ID” adjustments, set all the values “Off” so that all the buttons are enabled again.
Press the | button on the remote control and hold for more than 5 seconds. The |
“SHIPPING” menu is displayed and the lock is released when it disappears.