Panasonic TH-5065PF10UK manual Normalization

Page 49

Options Adjustments

 

Options

3/3

 

 

Slot power

Off

 

Power On Screen Delay

Off

 

V. lnstallation

Off

 

Rotate

Off

 

Serial Slot Select

Slot1

 

Item

Effect

 

 

 

Adjustments

 

 

 

Off

 

Auto

On

 

 

 

 

Off:

Power is not transmitted to the slot power.

 

 

Slot Power

Auto: Power is transmitted to the slot power only when main power is on.

 

On:

Power is transmitted to the slot power when main power is on or in the standby state.

 

 

 

 

Note: In some cases, power is transmitted to the slot power when main power is on or in the standby

 

 

state regardless of the slot power setting.

 

 

 

 

 

 

 

 

 

 

 

Off

1

2

3....

30

 

 

 

You can set the power-on delay time of the displays to reduce the power load, when you press

to

 

turn on the multiple displays that are set together, for example, on MULTI DISPLAY system.

 

 

Set each display’s setting individually.

 

 

 

Off:

 

The display will be turned on at the same time as

is pressed.

 

 

1 to 30 (sec.): Set the power-on delay time (second).

 

 

Power On

Notes:

 

After pressing

, the display will be powered on with time delay depending on this setting.

 

 

 

 

 

 

Screen Delay

• During this function is working, the power indicator is blinking green.

 

This function also works when the power recovers from failure or after plugging off and in again the power cord.

After you unplug and plug the power cord in while the unit is in standby mode and also the power is being supplied to a terminal board, the unit will start supplying the power to the board with time delay according to the setting.

The power indicator lights up red first and it turns orange when the power starts being supplied to the board.

 

 

 

Off:

Sets fan to the horizontal installation mode.

V.Installation

 

 

On:

Sets fan to the vertical installation mode.

Off

On

Notes:

 

 

 

• This functions when display is turned on.

 

 

 

 

 

 

• Turn up the power switch for the upward direction when you set Display vertically.

 

 

 

 

 

Rotate

 

 

Off:

Does not rotate the image.

Off

On On:

Rotates the image 180 degrees.

 

Serial Slot

 

 

Slot1

Slot2

Slot3

 

 

Selects the slot which communicates serial.

Select

 

 

 

 

Note: The setting of an external command can be set only from the fixed serial terminal. (see page 12)

 

 

 

Normalization

When both main unit buttons and remote control are disabled due to the “Button lock”, “Remocon User level” or “Remote ID” adjustments, set all the values “Off” so that all the buttons are enabled again.

Press the

button on main unit together with

button on the remote control and hold for more than 5 seconds. The

“SHIPPING” menu is displayed and the lock is released when it disappears.

49

Image 49
Contents English Operating Instructions Manual de instruccionesModel No. Número de modelo Please keep this manual for future referenceRisk of Electric Shock Do not Open Important Safety Instructions Table of Contents Canadian Notice FCC CautionTrademark Credits When using the Plasma Display Safety PrecautionsSafety Precautions / Maintenance MaintenanceSetup AC Power Supply CordAccessories Supplied AccessoriesRemote Control Batteries AC cord fixing ConnectionsMonitor terminal SeeOptional Terminal ConnectionsBoard Insert Slot Equivalent of Dual Covered HDMITerminal Board BNC Component VideoPC Input Terminals connection Signal Names for Mini D-sub 15P ConnectorSerial Terminals connection CommandCommunication parameters Basic format for control dataComponent / RGB connection Hdmi connectionRCA-BNC DVDConnecting the AC cord plug to the Plasma Display Power on / OFFConnecting the plug to the Wall Outlet Power on / OFF Main Power On / Off Switch Power Indicator Remote control sensor Volume AdjustmentBasic Controls Menu Screen on / OFFBasic Controls To Sound adjust menu To Picture adjust menu Pressed Press to select SeeOn-Screen Menu Displays Menu button on the unit can also beOn-Screen Menu Displays Power on Time Power OFF TimeComponent Initial selections Selecting the input signalSelecting the On-Screen Menu Language INPUT1 INPUT2A INPUT2B INPUT3 PCNormal Full During Multi PIP OperationsSize / DOT Clock / Clock Phase / 11 Pixel Mode Adjusting POS. /SIZEPress to adjust POS. /SIZE During COMPONENT, RGB and PC input signalAdjusting POS. /SIZE Multi PIP On Sets Advanced PIP mode Off Sets normal two screen display modeAdvanced PIP Press to confirmStandard Picture AdjustmentsDynamic CinemaPicture Adjustments Advanced SettingsBass Sound AdjustmentMID TrebleSDI Sound Output Sound AdjustmentSurround MuteDigital Zoom Press to set up DAY or Present Time of DAY Present Time SetupButton Forward Display the SET UP Timer Screen Press to select SET UP TimerPower on Time / Power OFF Time Start setting Mode selectionScreensaver For preventing image retention Negative / Scroll selectionReduces screen image retention Setup of Screensaver TimeScreensaver For preventing image retention OFF Dark MID Bright Side BAR AdjustPress to exit from Screensaver Customizing the Input labels Reduces power consumptionAddition sign Selected Input How to setup Multi Display SET UP for Multi DisplayIf you set Multi Display Setup to on Portrait Setup will be unavailablePress to select Seam Hides Video Press to select OFF, on SET UP for Multi DisplayDisplay Number locations for each arrangement Examples ID remote control button operation ID Remote Control FunctionID Cancellation Press to select OFF , onHow to setup Portrait SET UP for PortraitPress to select Seam Hides Video Display the image of the selected Location Location setting When Portrait Setup onViewing Area and Location Viewing Area LocationComponent / RGB in Select SET UP for Input Signals3D Y/C Filter For Ntsc AV images Component RGBPress Action button Press to exit from adjust mode SET UP for Input SignalsVideo NR / Block NR / Mosquito NR Refresh RatePulldown Color System / Panasonic AutoColor System Sync Setting RGB sync signalFREQ. kHz / V-FREQ. Hz Displays the H Horizontal / V Vertical frequencies Options1/3 Options AdjustmentsOff Initial VOL Sets normal volume Level Options AdjustmentsWhen Disable is set, the Off-timer is cancelled Normalization Weekly Command Timer Press to select Time / Command Press to select a command numberTime Set the time to execute a command program Press to set each itemShipping condition Plasma Display panel TroubleshootingCOMPONENT/RGB/PC/VIDEO input signals Video input Hdmi COMPONENT/RGB/PC/VIDEO input signalsMHz Active pixels Pixels Active lines Lines VGA60Command list of Weekly Command Timer TH-50PF10UK TH-65PF10UK SpecificationsLimits and Exclusions Limited Warranty Statement Panasonic Professional Display Company Customer’s RecordExecutive Office Panasonic Canada Inc