4.10 ADVANCED MENU ___REMOTE
Move the cursor to “REMOTE” and press ”ENTER”. The screen will show the following options.
REMOTE
TITLE | DEVICE | ID | PROTOCOL | RATE |
01 | PTZ | 001 | P - D | 02400 |
02 | CAMERA | 002 | NORMAL | 02400 |
03 | CAMERA | 003 | NORMAL | 02400 |
04 | CAMERA | 004 | NORMAL | 02400 |
1)TITLE:
Title of each camera.
2)DEVICE:
Select to control a normal camera or a PTZ camera for each channel.
3)ID:
Set the ID number (0 ~ 255) of PTZ camera.
Note: After connecting to a PTZ camera correctly, the default ID of PTZ camera will be shown on the screen.
4)PROTOCOL:
Select NORMAL (our protocol) or
5)RATE:
Set the baud rate of each channel (2400, 4800, 9600, 19200, 57600). For the connected cameras, such as PTZ and speed dome cameras, etc., please make sure the baud rate setting is the same as the setting here.
PTZ Camera Connection:
1)Connect the PTZ camera with indicated power supply.
2)Connect the PTZ camera video output to the DVR video input port with a coaxial cable and BNC connector.
3)Connect
Note: For detailed camera ID, protocol and baud rate setup at DVR side, please refer to the description above. For detailed camera ID, protocol and baud rate setup at remote AP software side, please refer to “Device” at page 39 (AP software system configuration). For detailed PTZ control instructions, please refer to “Digital Device Control Panel ~ PTZ” at page 35.