Installation to Solid Concrete or Cinder Block
WARNING
•When installing Westinghouse wall mounts on cinder block, verify that you have a minimum of
•Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
•Make sure that the wall will safely support the combined load of the equipment and all attached hardware and components.
1 | Make sure that tilt assembly (B) is level, use it as a |
template to mark two mounting holes. Drill two 1/4" |
(6 mm) dia. holes to a minimum depth of
(64 mm). Insert anchors (C) in holes flush with wall as shown (right). Place tilt assembly over anchors and secure with two #14 x
WARNING
•Tighten screws so that wall plate is firmly attached, but do not overtighten. Overtightening can damage screws, greatly reducing their holding power.
•Never tighten in excess of 80 in. • lb (9 N.M.).
WARNING
•Always attach concrete expansion anchors directly to
•Never attach concrete expansion anchors to concrete covered with plaster, drywall, or other finishing mate- rial. If mounting to concrete surfaces covered with a finishing surface is unavoidable, the finishing surface must be counterbored as shown below. Be sure concrete anchors do not pull away from concrete when tightening screws. If plaster/drywall is thicker than 5/8", custom fasteners must be supplied by installer.
1 | concrete |
| |
| surface |
|
|
C
Drill holes and insert anchors (C).
2 | B |
|
G C
Place assembly (B) over anchors (C) and secure with screws (G).
3
Tighten all fasteners.
SOLID |
|
|
CONCRETE | CINDER |
|
| BLOCK | |
C |
| |
|
|
|
| INCORRECT |
VIEW | wall | concrete |
plate |
| |
|
| |
CUTAWAY |
| plaster/ |
| dry wall | |
|
|
CORRECT
wall plate | concrete |
| plaster/ |
| drywall |
B
G
5 of 8 | ISSUED: |