Sharp PN-V602 Multiple monitor connection, Connections, Connection with RS-232 cable

Page 8

Connections

Multiple monitor connection

[Example]

 

Remote control sensor box

 

(Supplied with the PN-ZR01 (optional))

 

 

 

Second monitor

First monitor

 

Secondary

Primary

 

(Expansion unit)

(Main unit)

 

ID No.: 2

ID No.: 1

 

 

 

 

Third monitor

Fourth monitor

 

Secondary

Secondary

 

(Expansion unit)

(Expansion unit)

 

ID No.: 3

ID No.: 4

 

 

 

 

■ Connection with RS-232 cable

If you connect the monitor in a daisy chain using RS-232 cable, using the monitor buttons on the primary (main unit), settings are copied to the secondary (expansion unit) and operation from the primary can perform operation for all monitors. Setting each ID No. in the monitor is required.

The first monitor will be set as primary (main unit) and the second monitor and beyond will be secondaries (expansion units).

Connect the RS-232C cables in order, starting with the first monitor (primary monitor). If monitors are connected in a different order they may not be operable.

First monitor: primary Second monitor: secondary

*Always install the remote control sensor box on the primary monitor.

■ Connection with video cable

May vary depending on the system being used.

If using the PC/AV DVI-D terminal, up to 5 monitors can be connected in a daisy chain. (When the PN-ZB02 is attached)

First monitor

Second monitor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PC/AV DVI-D

PC/AV DVI-D

PC/AV DVI-D

input terminal

output terminal

input terminal

Digital signal (DVI) cables

(commercially available)

To PC digital RGB output terminal

shows the signal flow

RS-232C

RS-232C

RS-232C

output terminal

input terminal

output terminal

RS-232 straight cable (commercially available)

Third monitor: connects to secondary RS-232C input terminal

Connect the third monitor and other monitors in the same manner.

Up to 25 monitors can be connected. (Depending on the length of the cable used and the surrounding environment.) ID Number is set with the primary monitor’s buttons. If you set AUTO ASSIGN ID No., located in the menu of the monitor to ON, the ID No. will be automatically assigned in order from the primary.

E6

Image 8
Contents PN-V602 Live EarthNeutral Dear Sharp Customer ContentsImportant Information Safety Precautions Safety Precautions Safety InstructionMounting Precautions Supplied Components ConnectionsMultiple monitor connection ConnectionsConnection with RS-232 cable Connection with video cableFor the monitor Landscape orientation Portrait orientation Installing the batteriesConnection with the control kit optional Turning Power On/Off Turning on the main powerTurning power on/off NDate/time settingCher Client Table des matièresInformation Importante Précautions DE Sécurité Précautions DE Sécurité Suite Mesures DE SécuritéPrécautions Pour LE Montage Lorsque le PN-ZB02 optionnel est raccordé Composants fournisConnexions Connexion de plusieurs moniteurs ConnexionsConnexion avec le câble vidéo Connexion avec le câble RS-232Pour le moniteur en Position horizontale Position verticale Connexion au récepteur de télécommande optionnelMise en place des piles NRéglage de la date/heure Mise sous tension et hors tensionMise sous/hors tension Información Importante Estimado Cliente DE SharpPrecauciones DE Seguridad Precauciones DE Seguridad Continuación Instrucciones DE SeguridadPrecauciones DE Montaje Componentes suministrados ConexionesConexión de múltiples monitores ConexionesConexión con cable de vídeo Conexión con cable RS-232Conexión con el kit de control opcional Instalación de las pilasEncendido/apagado Encendido/apagadoNAjuste de fecha y hora LED indicador Botón de encendido de conexiónPage 11HKS1 TINSE1193MPZZ1