JVC AV-20N3/D, AV-20NMG3/-A, AV-20NMG3B service manual Colour Ⅱ

Page 24

AV-20N3

 

 

 

 

 

 

 

AV-20NMG3

 

 

 

 

 

 

 

AV-20NMG3B

 

 

 

 

 

 

 

Item

Measuring

Test point

Ad justment part

 

Description

instrument

 

 

 

 

 

 

 

Ad justment

Signal

TP-47G/R

5. COLOUR

[Method of adjustment using measuring instrument]

of SUB

generator

 

 

 

 

 

 

 

 

 

 

 

 

COLOUR

Oscillo-

TP-E (#)

PAL COLOUR

1.

Input a PAL full field colour bar signal (75% white).

 

[CRT SOCKET

 

2.

Enter the SERVICE MENU.

 

 

scope

 

 

 

 

 

PWB]

 

3.

Select 2. V/C from SERVICE MENU.

 

 

 

 

 

 

Remote

 

 

4.

Select 5. COLOUR with the MENU /key.

 

control unit

 

 

 

 

 

5.

Set the initial setting value of PAL COLOUR with the MENU

 

 

 

 

 

 

 

 

 

 

 

- / + key.

 

 

 

 

 

 

6.

Connect the oscilloscope between TP-47G and TP-E (#).

 

 

 

 

B

7.

Adjust PAL COLOUR to bring the value of (A) in the illustration

 

 

 

R

 

 

to the voltage as shown given billow.

 

 

 

Mg

 

 

(Voltage difference between (W) and (G))

 

 

 

 

 

 

 

 

 

 

()

 

Model

Voltage(W-G)

 

 

 

 

 

 

AV-20N3

+14V

 

 

 

 

0V

 

AV-20N3/D

 

W

 

 

 

 

 

Y

(A)

()

 

AV-20NMG3

 

 

 

Cy

 

 

AV-20NMG3B

+10V

 

 

G

 

 

 

 

 

 

 

AV-20NMG3/-A

 

 

 

 

 

SECAM COLOUR

1.

Input a SECAM full field colour bar signal (75% white).

 

 

 

 

 

2.

Set the initial setting value of SECAM COLOUR with the MENU

 

 

 

 

 

 

- or + key.

 

 

 

 

 

 

3.

Adjust SECAM COLOUR to bring the value of (A) in the

 

 

 

 

 

 

illustration to the voltage as shown given billow.

 

 

 

 

 

 

(Voltage difference between (W) and (G))

 

 

 

 

 

 

Model

Voltage(W-G)

 

 

 

 

 

 

AV-20N3

+8V

 

 

 

 

 

 

AV-20N3/D

 

 

 

 

 

 

 

 

 

 

 

 

 

AV-20NMG3

 

 

 

 

 

 

 

AV-20NMGB

+10V

 

 

 

 

 

 

AV-20NMG3/-A

 

 

 

 

 

NTSC 3.58 COLOUR

1.

Input a NTSC 3.58 full field colour bar signal (75% white).

 

 

 

 

 

2.

Set the initial setting value of NTSC 3.58 COLOUR with the

 

 

 

 

 

 

MENU - / + key.

 

 

 

 

 

 

3.

Adjust NTSC 3.58 COLOUR to

bring the value of (A) in the

 

 

 

 

 

 

illustration to the voltage as shown given billow.

 

 

 

 

 

 

(Voltage difference between (W) and (G))

 

 

 

 

 

 

Model

Voltage(W-G)

 

 

 

 

 

 

AV-20N3

+11V

 

 

 

 

 

 

AV-20N3/D

 

 

 

 

 

 

 

 

 

 

 

 

 

AV-20NMG3

 

 

 

 

 

 

 

AV-20NMG3B

+10V

 

 

 

 

 

 

AV-20NMG3/-A

 

 

 

 

 

NTSC 4.43 COLOUR

When NTSC 3.58 is set, NTSC 4.43 will be automatically set at the

 

 

 

 

 

respective values .

 

24

No. 52025

Image 24
Contents Contents Specifications EntsAV-20N3 AV-20NMG3Safety Precautions Features Memory SCL 2/SDA2Micro Computer VIDEO/CHROMA Decorder SCL 1/SDA1Functions Front Panel Rear TerminalRemote Control Unit Main Difference List Part NameModel Name Specific Service Instructions Disassembly ProcedureSpeaker KEY Assignment of Remote Control Unit Service MenuSystem CONSTANT-Ⅰ System CONSTANT-ⅡSetting of System Constant SET Setting item Setting contentsUser Setting Values Setting item Setting valueInitial Setting Value of Service Menu Preset Sound System Do Not Adjust Setting itemPAL Secam Replacement of IC301 if V/C Decoder ProceduresLocations of Front Panel Buttons and LAM PS Service Adjustments Before Starting Service AdjustmentAdjustment Items Measuring Instrument and FixturesBasic Operation of Service Menu KEY Assignment of Remote Control Unit Service MenuMethod of setting C, 3.DEF and 4.VSM PresetSetup Tour Should be OFFService Menu Flow Chart Adjustment Locations Solder SideTOP UpperfocusAdjustments B1 Power SupplyFocus Adjustment If Circuit AdjustmentDelay Point PointAGC AGC Take Over OtherVideo / Chroma Circuit Adjustment Method of adjustment without measuring instrument SUB BrightAd justment Remote SUBColour Ⅱ Tint CRTSocket BL Adjust Ad justment part Description RemoteSecam Control unit BL ACKDeflection Circuit Adjustment PositionVSM Preset Setting VER. ScurveScurve TOPPurity / Convergence Adjustment Purity Adjustment# P/C Magnets Static Convergence Adjustment Dynamic Convergence AdjustmentReplacement of Chip Component Replacement StepsSoldering Iron AV-20N3 AV-20NMG3 AV-20NMG3B