JVC AV-20NMG3B, AV-20N3/D, AV-20NMG3/-A service manual Safety Precautions

Page 3

AV-20N3

AV-20NMG3

AV-20NMG3B

SAFETY PRECAUTIONS

1.The design of this product contains special hardware, many circuits and components specially for safety purposes. For continued protection, no changes should be made to the original design unless authorized in writing by the manufacturer.

Replacement parts must be identical to those used in the original circuits. Service should be performed by qualified personnel only.

2.Alterations of the design or circuitry of the products should not be made. Any design alterations or additions will void the manufacturer's warranty and will further relieve the manufacturer of responsibility for personal injury or property damage resulting therefrom.

3.Many electrical and mechanical parts in the products have special safety-related characteristics. T hese characteristics are often not evident from visual inspection nor can the protection afforded by them necessarily be obtained by using replacement components rated for higher voltage, wattage, etc. Replacement parts which have these special safety characteristics are

identified in the parts list of Service manual. Electrical components having su ch features are identified by shading on the schematics and by (!) on the parts list in Service manual. The use of a substitute replacement which does not have the same safety characteristics as the recommended

replacement part shown in the parts list of Service manual may cause shock, fire, or other hazards .

4.Do n't short between the LIVE side ground and ISOL ATED (NEUTRAL) side ground or EARTH side ground when

repairing.

Some model's power circuit is partly different in the GND. The difference of the GND is shown by the LIVE : (") side GND, the ISOLATED(NEUTRAL) : (#) side GND and EARTH : ($) side GND. Don't short between the LIVE side GND and

ISOLATED(NEUTRAL) side GND or EARTH side GND and never measure with a measuring apparatus (oscilloscope etc.) the LIVE side GND and ISOLATED(NEUTRAL) side GND or EARTH side GND at the same time.

If above note will not be kept, a fuse or any parts will be broken.

5.If any repair has been made to the chassis, it is recommended that the B1 setting should be checked or adjusted (See

ADJUSTMENT OF B1 POWER SUPPLY).

6.The high voltage applied to the picture tube must conform with

that specified in Service manual. Excessive high voltage can cause an increase in X-Ray emission, arcing and possible component damage, therefore operation under excessive high voltage conditions should be kept to a minimum, or should be prevented. If severe arcing occurs, remove the AC power

immediately and determine the cause by visual inspection (incorrect installation, cracked or melted high voltage harness, poor soldering, etc.). To maintain the proper minimum level of soft X-Ray emission, components in the high voltage circuitry including the picture tube must be the exact replacements or

alternatives approved by the manufacturer of the complete product.

7.Do not check high voltage by drawing an arc. Use a high voltage meter or a high voltage probe with a VTVM. Discharge the picture tube before attempting meter connection, by connecting

a clip lead to the ground frame and connecting the other end of the lead through a 10k2W resistor to the anode button.

8.When service is required, observe the original lead dress. Extra precaution should be given to assure correct lead dress in the high voltage circuit area. W here a short circuit has occurred, those components that indicate evidence of overheating should

be replaced. Always use the manufacturer's replacement components.

9.Isolation Check

(Safety for Electrical Shock Hazard)

After re-assembling the product, always perform an isolation check on the exposed metal parts of the cabinet (antenna

terminals, video/audio input and output terminals, Control knobs, metal cabinet, screwheads, earphone jack, control shafts, etc.) to be sure the product is safe to operate without danger of electrical shock.

(1)Dielectric Strength Test

The isolation between the AC primary circuit and all metal parts exposed to the user, particularly any exposed metal part having a return path to the chassis should withstand a voltage of 3000V AC (r.m.s.) for a period of one second.

(. . . . Withstand a voltage of 1100V AC (r.m.s.) to an appliance

rated up to 120V, and 3000V AC (r.m.s.) to an appliance rated 200V or more, for a period of one second.)

This method of test requires a test equipment not generally found in the service trade.

(2)Leakage Current Check

Plug the AC line cord directly into the AC outlet (do not use a line

isolation transformer during this check.). Using a " Leakage Current Tester", measure the leakage current from each exposed metal part of the cabinet, particularly any exposed metal part having a return path to the chassis, to a known good earth ground (water pipe, etc.). Any leakage current must not exceed

0.5mA AC (r.m.s.).

However, in tropical area, this must not exceed 0.2mA AC (r.m.s.).

"Alternate Check Method

Plug the AC line cord directly into the AC outlet (do not use a line

isolation transformer during this check.). Use an AC voltmeter having 1000 ohms per volt or more sensitivity in the following manner. Connect a 150010W resistor paralleled by a 0.15F

AC-type capacitor between an exposed metal part and a known good earth ground (water pipe, etc.). Measure the AC voltage across the resistor with the AC voltmeter. Move the resistor connection to each exposed metal part, particularly any exposed

metal part having a return path to the chassis, and measure the AC voltage across the resistor. Now, reverse the plug in the AC outlet and repeat each measurement. Any voltage measured must not exceed 0.75V AC (r.m.s.). This corresponds to 0.5mA AC (r.m.s.).

However, in tropical area, this must not exceed 0.3V AC ( r.m.s.). This corresponds to 0.2mA AC (r.m.s.).

AC VOLTMETER (HAVING 1000 /V,

OR MOR E SENSITIVITY)

0.15μF AC-TYPE

 

 

PLACE THIS PROBE

1500 10W

ON EACH EXPOSED

METAL PART

GOOD EARTH GROUND

 

No.52025

3

Image 3
Contents Contents AV-20NMG3 SpecificationsEnts AV-20N3Safety Precautions VIDEO/CHROMA Decorder SCL 1/SDA1 FeaturesMemory SCL 2/SDA2 Micro ComputerFront Panel Rear Terminal FunctionsRemote Control Unit Main Difference List Part NameModel Name Disassembly Procedure Specific Service InstructionsSpeaker System CONSTANT-Ⅱ KEY Assignment of Remote Control UnitService Menu System CONSTANT-ⅠSetting item Setting value Setting of System Constant SETSetting item Setting contents User Setting ValuesInitial Setting Value of Service Menu Preset Sound System Do Not Adjust Setting itemPAL Secam Replacement of IC301 if V/C Decoder ProceduresLocations of Front Panel Buttons and LAM PS Measuring Instrument and Fixtures Service AdjustmentsBefore Starting Service Adjustment Adjustment ItemsKEY Assignment of Remote Control Unit Service Menu Basic Operation of Service MenuShould be OFF Method of settingC, 3.DEF and 4.VSM Preset Setup TourService Menu Flow Chart Upperfocus Adjustment LocationsSolder Side TOPIf Circuit Adjustment AdjustmentsB1 Power Supply Focus AdjustmentAGC Take Over Other Delay PointPoint AGCVideo / Chroma Circuit Adjustment SUB Method of adjustment without measuring instrumentSUB Bright Ad justment RemoteColour Ⅱ Tint CRTSocket BL ACK BL AdjustAd justment part Description Remote Secam Control unitPosition Deflection Circuit AdjustmentTOP VSM Preset SettingVER. Scurve ScurvePurity / Convergence Adjustment Purity Adjustment# P/C Magnets Dynamic Convergence Adjustment Static Convergence AdjustmentReplacement of Chip Component Replacement StepsSoldering Iron AV-20N3 AV-20NMG3 AV-20NMG3B