KV-2199XDK
SELF DIAGNOSTIC FUNCTION
The units in this manual contain a
The number of times the lamp flashes translates to a probable source of the problem. A definition of the STANDBY/TIMER lamp flash indicators is listed in the instruction manual for the user’s knowledge and reference. If an error symptom cannot be reproduced, the remote commander can be used to review the failure occurrence data stored in memory to reveal past problems and how often these problems occur.
1.DIAGNOSTIC TEST INDICATORS
When an errors occurs, the STANDBY/TIMER lamp will flash a set number of times to indicate the possible cause of the problem. If there is more than one error, the lamp will identify the first of the problem areas.
Result for all of the following diagnostic items are displayed on screen. No error has occured if the screen displays a “0”.
Diagnostic | No. of times | Probable | Detected | |
Item | STANDBY/TIMER | display/Diagnostic | Cause | Symptoms |
Description | lamp flashes | result | Location |
|
|
|
|
|
|
• Power does not | Does not light | — | • Power cord is not plugged | • Power does not come on. |
turn on |
|
| in. | • No power is supplied to the |
|
|
| • Fuse is burned out F4601 | TV. |
|
|
| (F) | • AC power supply is faulty. |
|
|
|
|
|
• +B overcurrent | 2 times | 002:000 or | • H.OUT Q511 is shorted. (A | • Power does not come on. |
(OCP) or |
| 002:001~255 | board) | • Load on power line is |
overvoltage |
| 003:001~255 | • IC701 is shorted. (C3 board) | shorted. |
(OVP) |
| 004:001~255 | • | • Has entered standby state |
• Vertical deflection |
| at the same time | board) | after horizontal raster. |
stopped |
|
| • IC 503 faulty (A board) | • Vertical deflection pulse is |
• Horizontal |
|
|
| stopped. |
deflection |
|
|
| • Power line is shorted or |
overdrive |
|
|
| power supply is stopped. |
|
|
|
|
|
• White balance | 5 times | 005:000 or | • G2 is improperly adjusted. | • No raster is generated. |
failure (no |
| 005:001~225 | (Note 2) | • CRT cathode current |
PICTURE) |
|
| • CRT problem. | detection reference pulse |
|
|
| • Video OUT IC701 is faulty. | output is small. |
|
|
| (C3 board) |
|
|
|
| • IC301 is faulty. (A board) |
|
|
|
| • No connection A board to |
|
|
|
| C3 board. |
|
|
|
|
|
|
• Micro reset | — | 101:00 or | • Discharge CRT (C3 Board) | • Power is shut down shortly, |
|
| 101:001~225 | • Static discharge | after this return back to |
|
|
| • External noise | normal. |
|
|
|
| • Detect Micro latch up. |
|
|
|
|
|
Note 1: If a + B overcurrent is detected, stoppage of the vertical deflection is detected simultaneously.
The symptom that is diagnosed first by the microcontroller is displayed on the screen. Note 2: Refer to screen (G2) Adjustment in section
– 4 –