GAS SUPPLY
BUILT-IN GAS LINE LOCATIONS
Note: Leave an access in the “island” structure for gas supply and regulator service not inside the grill structure. Weber® has a gas line and regulator access door (part # 36311) available from your dealer or call
Customer Service at
Plan View Left Side
|
|
|
| A (3 | 3/ ") |
|
|
|
|
| 4 |
|
|
| B (6 1/ | ") |
|
|
| 3 | 3/ " | 4 |
|
|
| C Gas Inlet | |||
6 | 1/ " |
| 4 | ||
Gas Inlet |
|
| |||
| 4 |
|
|
|
|
|
|
|
| Side view |
|
|
|
|
|
Dimensions |
| |||
| 28" Grill | 36" Grill | Tolerances | |
|
| |||
| A | 3 3/4" | 3 3/4"" | + 1/8" - 1/8" |
| B | 6 1/4" | 6 1/4" | + 1/8" - 1/8" |
| C | 2 1/2" | 2 1/2" | + 1/8" - 1/8" |
Note: Area should be kept clear of sharp, jagged, or extremely abrasive surfaces to avoid possible damage to gas supply lines. Exercise caution when pulling gas lines through
TYPICAL BULK PROPANE GAS SUPPLY INSTALLATION
We recommend that this installation be done by a LICENSED professional.
GENERAL SPECIFICATIONS FOR PIPING
Note - Contact your local municipality for building codes regulating outdoor gas grill installations. In absence of Local Codes, you must conform to the latest edition of the National Fuel Gas Code ANSI Z223.1/NFPA 54.
•This grill is designed to operate at 10.5 inches of water column pressure. A LP in line regulator may be necessary for this pressure.
CAUTION: IF YOUNG CHILDREN ARE IN
THE AREA, A LOCKING VALVE SHOULD BE CONSIDERED.
•Pipe compound should be used which is resistant to the action of liquid propane gas when gas con- nections are made.
•The gas connections must be firmly attached to rigid, permanent construction.
Note: The information provided in this manual is general for typical installations. We cannot cover all possible installation ideas. We recommend, prior to installation, that you contact your municipality for local building codes and your local fire department for installation verification.
If you have any questions, contact Customer Service at 1-800-446-1071
Table | Maximum Capacity of Pipe in Cubic Feet of Gas per Hour for Gas Pressures of 0.5 psi or Less and a Pressure Drop of 0.3 Inch | ||||||||||||||
|
|
|
|
| Water Column. (Based on a 0.60 Specific Gravity Gas) |
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Nominal | Internal |
|
|
|
|
|
| Length of Pipe (Feet) |
|
|
|
|
|
| |
Iron Pipe | Diameter |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Size | (Inches) | 10 | 20 | 30 | 40 | 50 | 60 | 70 | 80 | 90 | 100 | 125 | 150 | 175 | 200 |
(Inches) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1/4 | .364 | 32 | 22 | 18 | 15 | 14 | 12 | 11 | 11 | 10 | 9 | 8 | 8 | 7 | 6 |
3/8 | .493 | 72 | 49 | 40 | 34 | 30 | 27 | 25 | 23 | 22 | 21 | 18 | 17 | 15 | 14 |
1/2 | .622 | 132 | 92 | 73 | 63 | 56 | 50 | 46 | 43 | 40 | 38 | 34 | 31 | 28 | 26 |
3/4 | .824 | 278 | 190 | 152 | 130 | 115 | 105 | 96 | 90 | 84 | 79 | 72 | 64 | 59 | 55 |
1 | 1.049 | 520 | 350 | 285 | 245 | 215 | 195 | 180 | 170 | 160 | 150 | 130 | 120 | 110 | 100 |
1 1/4 | 1.380 | 1050 | 730 | 590 | 500 | 440 | 400 | 370 | 350 | 320 | 305 | 275 | 250 | 225 | 210 |
1 1/2 | 1.160 | 1600 | 1100 | 890 | 760 | 670 | 610 | 560 | 530 | 490 | 460 | 410 | 380 | 350 | 320 |
2 | 2.067 | 3050 | 2100 | 1650 | 1450 | 1270 | 1150 | 1050 | 990 | 930 | 870 | 780 | 710 | 650 | 610 |
2 1/2 | 2.469 | 4800 | 3300 | 2700 | 2300 | 2000 | 1850 | 1700 | 1600 | 1500 | 1400 | 1250 | 1130 | 1050 | 980 |
3 | 3.068 | 8500 | 5900 | 4700 | 4100 | 3600 | 3250 | 3000 | 2800 | 2600 | 2500 | 2200 | 2000 | 1850 | 1700 |
4 | 4.026 | 17500 | 12000 | 9700 | 8300 | 7400 | 6800 | 6200 | 5800 | 5400 | 5100 | 4500 | 4100 | 3800 | 3500 |
|
|
|
| ||||||||||||
| ©1997 National Fire Protection Association, Inc., and International Approval Services - U.S., Inc. All Rights Reserved. |
|
|
3