Transmission / Receiving Protocol
Transmission
[F6][Command][SetID][Data][CS][6F]
*[F6] : Start of Communication
*[Command] : Command set
*[Set ID] : You can adjust the set ID to choose desired monitor ID number in SETUP menu. See previous page. Adjustment range is 1~99.
*[DATA] : To transmit command data.Transmit‘FF’data to read status of command.
*[Cr] : Check Sum ASCII code ‘0x0D’
*[6F] : End of Communication
OK Acknowledgement
[F7][Command][SetID][Data][CS][7F]
*The Monitor transmits ACK(acknowledgement) based on this format when receiving normal data. At this time, if the data is data read mode, it indicates present status data. If the data is data write mode, it returns the data of the PC computer.
Error Acknowledgment
[F7][Command][SetID][FF][CS][7F]
*The Monitor transmits ACK(acknowledgement) based on this format when receiving abnormal data from
01.Power
:To control Power On/Off of the set
Transmission [F6][01][SetID][Data][CS][6F] Data 0 : Power Off 1 : Power On
OK Acknowledgement [F7][01][SetID][Data][CS][7F]
: To show Power On/Off
Transmission [F6][01][SetID][FF][CS][6F]
OK Acknowledgement [F7][01][SetID][Data][CS][7F]Data 0 : Off 1 : On
*In like manner,if other functions transmit‘FF’data based on this format, Acknowledgement data feed back presents status about each function.
02.Volume Mute
:To control volume mute On/Off of the set
Transmission [F6][02][SetID][Data][CS][6F]
Data 0 : Volume Mute Off (Volume On)
1 :Volume Mute On (Volume Off)
OK Acknowledgement [F7][02][SetID][Data][CS][7F]
03. Screen Mute
:To select screen mute On/Off
Transmission [F6][03][SetID][Data][CS][6F]
Data 0 : Screen Mute Off (Picture On)
1 : Screen Mute On (Picture Off)
OK Acknowledgement [F7][03][SetID][Data][CS][7F]
04.Contrast
:To adjust screen contrast. You can also adjust contrast in the PICTURE menu.
Transmission [F6][04][SetID][Data][CS][6F] Data Min : 0 ~ Max : 64
* Refer to‘Real data mapping1’.
OK Acknowledgement [F7][04][SetID][Data][CS][7F]
ENG
PRESTIGIO P400MW / P460MW | 37 |