ENG
OK Acknowledgement [F7][27][SetID][Data][CS][7F]
19. PIP Position
:To select PIP Position. You can also adjust PIP Position. In the PIP menu.
Transmission [F6][28][SetID][Data][CS][6F]
Data 0 : Right Bottom 1 : Left Bottom
2 : Left Top 3 : Right Top
OK Acknowledgement [F7][28][SetID][Data][CS][7F]
20. PIP Audio Output
:To select PIP audio output.You can also adjust Audio Output. In the PIP menu.
Transmission [F6][29][SetID][Data][CS][6F] Data 0 : Main 1 : Sub
OK Acknowledgement [F7][29][SetID][Data][CS][7F]
21. Clock
:To adjust clock. You can also adjust Clock. In the PC Control of SETUP menu.
Transmission [F6][2A][SetID][Data][CS][6F] Data Min : 0 ~ Max : 64
* Refer to‘Real data mapping1’.
OK Acknowledgement [F7][2A][SetID][Data][CS][7F]
22. Phase
:To adjust phase.You can also adjust Phase. In the PC Control of SETUP menu.
Transmission [F6][2B][SetID][Data][CS][6F] Data Min : 0 ~ Max : 64
* Refer to‘Real data mapping1’.
OK Acknowledgement [F7][2B][SetID][Data][CS][7F]
23.Horizontal
:To adjust horizontal. You can also adjust
Transmission [F6][2C][SetID][Data][CS][6F] Data Min : 0 ~ Max : 64
* Refer to‘Real data mapping2’.
OK Acknowledgement [F7][2C][SetID][Data][CS][7F]
24. Vertical
:To adjust vertical.You can also adjust
Transmission [F6][2D][SetID][Data][CS][6F] Data Min : 0 ~ Max : 64
* Refer to‘Real data mapping2’.
OK Acknowledgement [F7][2D][SetID][Data][CS][7F]
25.Auto
:To execute auto command.You can also execute Auto. In the PC Control of SETUP menu.
Transmission [F6][2E][SetID][Data][CS][6F] Data 0 : Execute
OK Acknowledgement [F7][2E][SetID][Data][CS][7F]
40 | PRESTIGIO P400MW / P460MW |