Error messages

Error messages

Display

ODescription

OVTR operation and corrective action

 

 

 

 

 

E-20

If condensation is detected, the error number

 

flashes and the unit transfers to eject mode. The

DEW

drum rotates after the cassette is ejected to

 

eliminate the condensation.

 

Once the unit is released from condensation

 

status, the error message display is cleared and

 

the VTR is able to be used.

 

OIf condensation is detected in the eject mode,

 

the drum starts rotating as soon as it is

 

detected.

 

OIf condensation is detected when the cassette

 

has been inserted, the drum rotation is

 

stopped, and after the tape is ejected, the

 

drum starts rotating.

 

VTR: EJECT

 

OLeave the power on and wait.

 

 

E-29

The unit switches to eject mode and if the

 

cassette fails to move up within 6 seconds, this

FRONT LOAD

error number flashes on the display.

MOTOR

OIf the cassette does not move down inside the

 

machine even when 6 seconds have elapsed

 

since the cassette was inserted, the VTR is

 

transferred to the eject mode.

 

VTR: STOP

 

OSet the POWER switch to OFF and then to

 

ON again.

 

 

E-31

If the unloading operation is not completed

 

within 6 seconds, this error number flashes on

LOADING

the display.

MOTOR

OWhen the loading operation is not completed

 

within 6 seconds, the VTR is transferred to the

 

eject (unloading) mode.

 

VTR: STOP

 

OSet the POWER switch to OFF and then to

 

ON again.

 

 

E-35

If there is no response from the servo

 

microcomputer for 1 second or more, this error

SERVO

number flashes on the display.

CONTROL

VTR: STOP

ERROR

OSet the POWER switch to OFF and then to

 

ON again.

 

 

E-37

If 10 seconds or more elapses and the servo

 

microcomputer has not followed orders issued

SERVO COMM

by the system control microcomputer, this error

ERROR

number flashes on the display.

 

VTR: STOP

 

OSet the POWER switch to OFF and then to

 

ON again.

 

 

E-38

If automatic adjustment of the reel and capstan

 

rotation in eject status was not performed

SERVO FG

correctly when the power was turned on, this

ERROR

error number flashes on the display.

 

VTR: STOP

 

OSet the POWER switch to OFF and then to

 

ON again.

 

 

Display

ODescription

OVTR operation and corrective action

 

 

 

 

 

E-51

If the take-up reel rotates without engaging for a

 

specific period of time during the start or end

FRONT LOAD

processing operation while loading is underway

ERROR

(half position), this error number flashes on the

 

display.

 

VTR: STOP

 

OSet the POWER switch to OFF and then to

 

ON again.

 

 

E-52

If the take-up reel fails to take up the tape while

 

the tape is traveling in the state where the total

W-UP REEL

amount of the tape has not yet been detected

NOT ROTA

after the cassette was inserted, this error

 

number flashes on the display.

 

VTR: STOP

 

OSet the POWER switch to OFF and then to

 

ON again.

 

 

E-53

If there is an abnormally large discrepancy

 

between the amount of tape taken up by the

WINDUP

take-up reel and the amount of tape supplied by

ERROR

the supply reel while the tape is traveling after

 

the total amount of the tape begins to be

 

detected, this error number flashes on the

 

display.

 

VTR: STOP

 

OSet the POWER switch to OFF and then to

 

ON again.

 

 

E-55

If the tape has not been taken up during

 

unloading, this error number flashes on the

UNLOAD

display.

ERROR

VTR: STOP

 

OSet the POWER switch to OFF and then to

 

ON again.

 

 

E-57

If the start or end processing operation is not

 

completed, this error number flashes on the

S-FF/REW

display.

TIMEOVER

VTR: STOP

 

OSet the POWER switch to OFF and then to

 

ON again.

 

 

E-59

If the cylinder motor speed is abnormally low,

 

this error number flashes on the display.

DRUM ROTA

VTR: STOP

TOO SLOW

OSet the POWER switch to OFF and then to

 

ON again.

 

 

E-60

If the cylinder motor speed is abnormally high,

 

this error number flashes on the display.

DRUM ROTA

VTR: STOP

TOO FAST

OSet the POWER switch to OFF and then to

 

ON again.

 

 

E-61

If the capstan motor speed is abnormally low,

 

the error number flashes on the display.

CAP ROTA

VTR: STOP

TOO SLOW

OSet the POWER switch to OFF and then to

 

ON again.

 

 

68

Image 68
Contents Operating Instructions Model No. AJ- P$ this Apparatus Must be Grounded Contents IntroductionFeatures Parts and their functions Front panelPlay button REC buttonStop button FF buttonPlayer RecorderJOG ShtlPreview ReviewVAR REC LEVEL, PB LevelUnity Preset RegenOFF EXTDisplay panel REC INH Edit RECREC OUT Rear panelIN/OUT Parallel Remote connector Analog Audio OUT connectorsCmonitor OUT connectors = Signal GND terminalConnections Source machineRecorder OFFAV monitor Reference signal Generator Connections with editing controllerRecorder AV monitor Editing controllerTapes Consumer-use DV and Dvcam cassettesCassettes Cassette sizeJog mode Jog/ShuttleManual editing SD955B Preroll SD955BAssemble InsertSwitch settings and adjustments When using the AJ-SD955B as the recorderWhen using the AJ-SD955B as the player Automatic editing deck-to-deckSD955BMatch frame processing function Selecting the editing modeAssem How to calculate the duration Checking and previewing edit pointsModifying edit points Re-registering an edit pointExecuting and reviewing automatic editing Post-rollingRetry function Auto tag function recorder sideAudio split editing SD955B $ Duration display Between the video in and OUT pointsBetween the audio in and OUT points Match frame processing systemVariable memory editing operation procedure $ Selecting the variable memory mode$ Releasing variable memory mode Variable memory editing SD955BChanging the settings Setup initial settingsSetup menus Setting and releasing the lock modeChanging the file SystemLock mode can be set Lock mode can be set Counter displayLoading user files Menu screen Load/saveSaving user files Menu screenSystem menu SET UP Level OffsetSYS SC/H LocalUser menu Basic User menu BasicOperation Memory stop function REC INH LampEject SW INHInterface Edit Edit Rplcec Confi EditAUD Edit AUD Edit OUTTape Protect Time Code RUN Mode Vitc OUTSBC VauxYC SEP Mode INT SGOUT Vsync Mute SELESR Mode CCR ModeSetup CmpstUmid REC CC RECWide Select Umid POS Umid GENINT CH1 in LV CH2 in LVCH3 in LV CH4 in LVMoni CH SEL PCMREC CH1 REC CH2User menu Audio Blank ADD LineREC LINE1 REC LINE2Teletext SEL REC LINE3REC LINE4 Number of lines which can be set for Teletext Menu Setting the internal time code Time code/user bitTime code User bitVitc Setting the external time codeLTC Operation mode Superimpose screenCharacters displayed Display positionVideo output signals and servo reference signal External synchronization of video output signalsREF Video input signal Internal synchronizationServo reference signal Fade is performed instantaneously to eliminate the noise Audio signal aAudio V fade function Audio recording channel and monitor output selection Printed circuit boardAudio recording channel Monitor output channelStandard rack Fasten it to the rack with set screws Rack mountingRack-mounting adaptors Video head cleaning MaintenanceCondensation Attaching the dust cover Error messages Diag menu $ Displaying the Diag menu $ Warning information display$ Displaying the Hours Meter information $ Umid information displayHigh Error Rate Unknown SIGInvalid Video SIG Invalid Audio SIGError messages Tension VTR Stop Error Torque VTR Stop ErrorReel Rota VTR Stop TOO Fast ReelHardware specifications External interface specificationsConnector specifications RS-232C interfaceSend format controller PC 5 VTR Software specifications ProtocolCommunication parameters Return format VTR 5 controller PC Error code table$ When the communication has terminated normally Command table $ Commands relating to operation control$ Commands relating to inquiries CTL/TC Data STX QCD ETXRequest Status STX QOP ETXPrecautions to observe when using the Sdti signals Source Reference signal GeneratorSdti signals Sdti interfaceRemote OUT Connector signalsRemote IN/OUT RS-232C SUB 25-pin crossover cable supportedSpecifications $Video input connector$Digital video $Digital IN/Analog component OUTOther Input/Output Connectors Panasonic Broadcast & Television Systems Company Eastern ZoneWestern Zone Technical Support