Error Code Message Information
BAT0012 Message The storage battery for disk drive bay <
bay
> has failed.
LCD Message Battery for disk drive bay <
bay
> has failed. Check battery.
Details Verify the cable connection between the storage battery and the controller.
Action Verify the storage battery installation.
BAT0014 Message The storage battery for disk drive bay <
bay
> is absent.
LCD Message Battery for disk drive bay <
bay
> is absent. Check battery.
Details Verify the cable connection between the storage battery and the controller.
Action Verify the storage battery installation.
BAT0015 Message The <
name
> battery is low.
Details The low <
name
> battery may impact system performance negatively.
Action Recharge the <
name
> battery if possible. If the problem continues replace the <
name
>
battery.
BAT0017 Message The <
name
> battery has failed.
LCD Message The <
name
> battery has failed. Check battery.
Details The <
name
> battery is either missing, bad, or unable to charge due to thermal issues.
Action Check system fans. Replace the <
name
> battery.
BAT0019 Message The <
name
> battery is absent.
LCD Message The <
name
> battery is absent. Check battery.
Details The failed or missing <
name
> battery may reduce system performance.
Action Check system fans. Replace the <
name
> battery.
CBL0006 Message Multiple storage controllers are incorrectly connected to the same backplane <
Bay ID
>.
Details Unsupported backplane configuration.
Action Check backplane configuration. Reconnect cable. If the issue persists, see Getting Help.
CPU0000 Message CPU <
number
> has an internal error (IERR).
LCD Message CPU <
number
> has an internal error (IERR).
Details System event log and OS logs may indicate that the exception is external to the
processor.
Action Review System Event Log and Operating System Logs. If the issue persists, see Getting
Help.