Error Code Message Information
SEL1304 Message The PXE server not found.
Details PXE is one way to boot a system from the network.
Action Check the network and PXE server configuration.
SEL1306 Message Invalid boot sector found.
Details The disk in the drive is not formatted correctly or does not contain the necessary operating
system files.
Action Replace diskette with a bootable disk.
SEL1308 Message A time-out occurred while waiting for user to select a boot source.
Details The system has failed to boot to an operating system and needs the user to select a boot
source.
Action Select boot source within the time allowed.
SEL1501 Message Chassis management controller (CMC) redundancy is lost.
Details An action or failure has taken place that breaks CMC redundancy.
Action Check the CMC network cables and network connections. Check that CMC firmware
versions match.
SEL1502 Message Chassis management controller (CMC) redundancy is degraded.
Details An action or failure has taken place that breaks CMC redundancy.
Action Check the CMC network cables and network connections. Check that CMC firmware
versions match.
SEL1504 Message The chassis management controller (CMC) is not redundant. Insufficient resources to
maintain normal operations.
Details There is not enough available power for two CMC's to operate.
Action Check the overall power consumption and power status.
SEL1506 Message Lost communications with Chassis Group Member <
number
>.
Details The primary CMC has lost communication with the indicated member CMC.
Action Check the network cable and network connections.
SEL1508 Message Member <
number
> could not join the Chassis Group.
Details The indicated member CMC is a leader of a different CMC stacking group.
Action Check if member CMC is a leader of a different chassis group.
116