Error Code Message Information
ASR0106 Message The watchdog timer expired.
Details The operating system or an application failed to communicate within the time-out period.
Action Check the operating system, application, hardware, and system event log for exception
events.
ASR0107 Message The watchdog timer pre-timeout interrupt was initiated.
Details The operating system or an application failed to communicate within the time-out period.
Action Check the operating system, application, hardware, and system event log for exception
events.
BAT0000 Message The system board battery is low.
Details The system board battery is either missing, bad, or unable to charge due to thermal issues.
Action Check system fans. Replace the system board battery.
BAT0002 Message The system board battery has failed.
LCD Message The system board battery has failed. Check battery.
Details The system board battery is either missing or bad.
Action See Getting Help.
BAT0004 Message The system board battery is absent.
LCD Message The system board battery is absent. Check battery.
Action Reinstall the system board battery.
BAT0005 Message The storage battery is low.
Details System has to remain powered on to charge the battery.
Action Allow the battery to charge. If the issue persists, see Getting Help.
BAT0007 Message The storage battery has failed.
LCD Message The storage battery has failed. Check battery.
Details Verify the cable connection between the storage battery and the controller.
Action Verify the storage battery installation.
BAT0010 Message The storage battery for disk drive bay <
bay
> is low.
Details System has to remain powered on to charge the storage battery.
Action Allow the storage battery to charge. If the issue persists, see Getting Help.
80