Error Code Message Information
|
| 5. | If the issue persists, see Getting Help. |
CPU0703 | Message | CPU bus initialization error detected. | |
| |||
| LCD Message | CPU bus initialization error detected. Power cycle system. | |
| Details | System event log and operating system logs may indicate that the exception is external | |
|
| to the processor. | |
| Action | 1. | Check system and operating system logs for exceptions. If no exceptions are |
|
| ||
|
|
| found, continue. |
|
| 2. | Turn system off and remove input power for one minute. |
|
| 3. | Ensure the processor is seated correctly. |
|
| 4. | Reapply input power and turn system on. |
|
| 5. | If the issue persists, see Getting Help. |
CPU0704 | Message | CPU <number> machine check error detected. | |
| |||
| LCD Message | CPU <number> machine check error detected. Power cycle system. | |
| Details | System event log and operating system logs may indicate that the exception is external | |
|
| to the processor. | |
| Action | 1. | Check system and operating system logs for exceptions. If no exceptions are |
|
| ||
|
|
| found, continue. |
|
| 2. | Turn system off and remove input power for one minute. |
|
| 3. | Ensure the processor is seated correctly. |
|
| 4. | Reapply input power and turn system on. |
|
| 5. | If the issue persists, see Getting Help. |
CPU0801 | Message |
| |
| LCD Message |
| Details |
| Action |
CPU <number> voltage regulator module failed.
CPU <number> voltage regulator module failed.
System performance may be degraded or the system may fail to operate.
1.Turn system off and remove input power for one minute.
2.Reapply input power and turn system on.
3.Ensure the processor is seated correctly.
4.If the issue persists, see Getting Help.
CPU0802 Message
Details
Action
A predictive failure detected on CPU <number> voltage regulator module.
System performance may be degraded or the system may fail to operate.
1.Turn system off and remove input power for one minute.
2.Reapply input power and turn system on.