Error Code Message Information
| Details | The current power operational mode is |
|
| exception, a power supply inventory change, or a system power inventory change. |
| Action | Check the event log for power supply failures. Review system configuration and power |
|
| consumption. |
PWR1001 | Message | The system performance was degraded. |
| ||
| LCD Message System performance degraded. Check PSUs and system configuration. | |
| Details | To avoid shutdown, system performance has been degraded. |
| Action | Review system configuration and system logs for thermal or environmental failures and |
|
| warnings. |
PWR1002 | Message | The system performance degraded because of thermal protection. |
| ||
| Details | To avoid shutdown, system performance has been degraded. |
| Action | Review system configuration and system logs for thermal or environmental failures and |
|
| warnings. |
PWR1003 | Message | The system performance degraded because cooling capacity has changed. |
| ||
| Details | The current power supply configuration does not meet the platform requirements to enable |
|
| redundancy. If a power supply fails the system may shutdown. |
| Action | If unintended, review system configuration and power consumption and install power |
|
| supplies accordingly. Check power supply status for failures. |
PWR1004 | Message | The system performance degraded because power capacity has changed. |
| ||
| Details | The system may power down or operate in a performance degraded state. |
| Action | Check the event log for power supply failures. Review system configuration and power |
|
| consumption and upgrade or install power supplies accordingly. |
PWR1005 | Message | The system performance degraded because the |
| ||
| Details | The |
| Action | If unintended, review system configuration changes and power policy. |
PWR1006 | Message | The system halted because system power exceeds capacity. |
| ||
| LCD Message System power demand exceeds capacity. System halted. | |
| Details | The system halted because system power exceeds capacity. |
| Action | Review system configuration, upgrade power supplies or reduce system power |
|
| consumption. |
PWR1007 | Message | The system performance degraded because power exceeds capacity. |
|
108