Dell M620 Redundancy. If a power supply fails the system may shutdown, PWR1005 Message

Models: M620

1 133
Download 133 pages 45.77 Kb
Page 108
Image 108

Error Code Message Information

 

Details

The current power operational mode is non-redundant because of a power supply

 

 

exception, a power supply inventory change, or a system power inventory change.

 

Action

Check the event log for power supply failures. Review system configuration and power

 

 

consumption.

PWR1001

Message

The system performance was degraded.

 

 

LCD Message System performance degraded. Check PSUs and system configuration.

 

Details

To avoid shutdown, system performance has been degraded.

 

Action

Review system configuration and system logs for thermal or environmental failures and

 

 

warnings.

PWR1002

Message

The system performance degraded because of thermal protection.

 

 

Details

To avoid shutdown, system performance has been degraded.

 

Action

Review system configuration and system logs for thermal or environmental failures and

 

 

warnings.

PWR1003

Message

The system performance degraded because cooling capacity has changed.

 

 

Details

The current power supply configuration does not meet the platform requirements to enable

 

 

redundancy. If a power supply fails the system may shutdown.

 

Action

If unintended, review system configuration and power consumption and install power

 

 

supplies accordingly. Check power supply status for failures.

PWR1004

Message

The system performance degraded because power capacity has changed.

 

 

Details

The system may power down or operate in a performance degraded state.

 

Action

Check the event log for power supply failures. Review system configuration and power

 

 

consumption and upgrade or install power supplies accordingly.

PWR1005

Message

The system performance degraded because the user-defined power capacity has changed.

 

 

Details

The user-defined power settings have affected system operation.

 

Action

If unintended, review system configuration changes and power policy.

PWR1006

Message

The system halted because system power exceeds capacity.

 

 

LCD Message System power demand exceeds capacity. System halted.

 

Details

The system halted because system power exceeds capacity.

 

Action

Review system configuration, upgrade power supplies or reduce system power

 

 

consumption.

PWR1007

Message

The system performance degraded because power exceeds capacity.

 

108

Page 108
Image 108
Dell M620 owner manual Redundancy. If a power supply fails the system may shutdown, PWR1005 Message