Pentair MiniMax Plus HP Series, PowerMax installation manual Powermax Wiring Diagram

Models: MiniMax Plus HP Series PowerMax

1 40
Download 40 pages 37.76 Kb
Page 33
Image 33
POWERMAX WIRING DIAGRAM

Rev

POWERMAX WIRING DIAGRAM

. G 1-22-04

EXTERNAL BOND LUG

TERMINATE SUPPLY SAFETY GROUND WIRE (GREEN) HERE GROUND SCREW WITH PAINT CUTTING WASHER

CHASSIS

SHEET METAL

CHASSIS

SHEET METAL

HIGH LIMIT

THERMAL SWITCHES

GRN

IF ORIGINAL FACTORY WIRING MUST BE REPLACED, INSTALLER MUST SUPPLY

UL OR CSA (IF CANADA) APPROVED WIRE, 18 GAUGE, 600V, 105 C TEMPERATURE RATING. THERMAL FUSE WIRING MUST BE REPLACED WITH UL OR CSA (IF CANADA) APPROVED WIRE, 18 GAUGE, 600V, 125 C TEMPERATURE RATING..

INTERCONNECTING WIRING TO APPLIANCE MUST CONFORM TO THE NATIONAL ELECTRICAL CODE OR SUPERCEDING LOCAL (WIRING) CODES.

THERMAL FUSE

RED

WHT/RED

L1-1

L1-2

T1

 

L2-1

L2-2

WATER PRESSURE

SWITCH

RED

RED

WHT

WHT

F1

F2

RED

MV

WHT

PV/MV

BLU

PV

IGNITION RETURN

PLUG

GAS VALVE

MV

PV/MV

PV

A-

WHT/BLK

BLK

W1

W2

GRN

 

 

RED

MV

 

T2

WHT

 

PLUG

ORG

 

 

WHT

MV/PV

 

 

BLU

PV

 

SPST. EXTERNAL ON/OFF SWITCH

GRN

1

5 4 3 2 1 2

6

3 2 1

1

2

3

4

ORG

P4

P7

 

PI0

 

P11

 

 

 

IGNITION MODULE

MV

MV/PV

PV

GND (BURNER)

GND

24 V

TH-W ( OPT )

SPARK

PowerMax Electronic Ignition Wiring Diagram

7

ORG

ORG

AIR PRESSURE

BLUE SWITCH

JUMPER REQUIRED IF NO REMOTE SWITCH 25D K .032 D.C TAB

J2 J3

CONTROL RELAY

CLOSE ON CALL

FOR HEAT

24V

PRESS

HLMT

TFUSE

J4

 

J7

 

1

1

 

 

AUX.

CONTACTS

 

 

 

TPROBE

J6

J8

J5

J9

SPA

COM

POOL

 

P6

P8

P5

P9

VLV

IGN MODULE

JI0

J11

1

1

THERMOSTAT

CIRCUIT BOARD

IGNITION WIRE

Manual backgroundSPARK IGNITER

GRN 24 VAC RELAY

FAN

MOTOR

WHTBLK

120 VAC

BLK

TEMPERATURE

BLKPROBE

POOL OFF SPA

THERMOSTAT SELECT SWITCH

P/N 471048

Page 33
Image 33
Pentair MiniMax Plus HP Series, PowerMax installation manual Powermax Wiring Diagram