MiniMax Plus Millivolt Wiring Diagram

Installation (contd.)

22

 

 

MINIMAX WIRING DIAGRAM (MILLIVOLT) DUAL THERM (HONEYWELL ELECTRONIC)

IF ORIGINAL FACTORY WIRING MUST BE REPLACED, INSTALLER MUST SUPPLY UL OR CSA (IF CANADA)

APPROVED WIRE, 18 GAUGE, 600V, 105 C˚ TEMPERATURE RATING. THERMAL FUSE WIRING MUST BE REPLACED WITH

UL OR CSA (IF CANADA) APPROVED WIRE,

18 GAUGE, 600V, 125 C˚ TEMPERATURE RATING.

INTERCONNECTING WIRING TO APPLIANCE MUST CONFORM TO THE NATIONAL ELECTRICAL CODE OR SUPERCEDING LOCAL (WIRING) CODES.

 

 

PILOT

 

 

TH/PP

WHT

GENERATOR

 

 

 

 

 

 

 

RED

 

 

 

TH

PP

 

SAFETY

PRESS

GAS VALVE

 

 

 

HI-LIMIT

SHUT-OFF

SWITCH

 

 

WHT

 

WHT

WHT

WHT

THERMAL

CUT-OFF

ORN

WHT

WHT

MiniMax Plus Millivolt Wiring Diagram

After 1-15-01

TH/PP

PP

TH

POT 1

POT 2

THERMOSTAT BOARD

SEN

POT

 

SENSOR

POOL

OFF

SPA

Figure 27.

REMOTE SWITCH DUAL THERM IID ONLY

3 Wire Remote

OUT

EXT SWITCH

JUMPER REQUIRED IF NO 2 WIRE REMOTE SWITCH

24 VAC PRESS HILMT TFUSE

VALVE

IGNITION MOD

 

 

 

 

 

RETURN

THERMOSTAT CIRCUIT BOARD

SPA COM POOL

TPROBE

REMOTE POOL/OFF/SPA

THERMOSTAT SELECT SWITCH

FRONT PANEL

POOL/

OFF/SPA

THERMOSTAT SELECT SWITCH

Figure 28.

2 Wire Remote

OUT

EXT SWITCH

JUMPER REQUIRED IF NO 2 WIRE REMOTE SWITCH

24 VAC PRESS HILMT TFUSE

VALVE

IGNITION MOD

RETURN

THERMOSTAT CIRCUIT BOARD

SPA COM POOL

TPROBE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FRONT PANEL

 

POOL/OFF/SPA

 

THERMOSTAT SELECT SWITCH

Figure 29.

 

NOTE: When connecting a remote control to the MiniMax Plus, you must install the low voltage thermostat wires in separate conduit from ANY line voltage wires. Failure to follow these instructions will cause the thermostat relay to react erratically.

P/N 471048

Rev. G 1-22-04

Page 22
Image 22