Error Code Message Information
Details The controller received a SMART error from the drive. The drive is operational but needs replacement.
Action The drive will need replacement at the next service window.
PDR1016
PDR1024
PST0128
PST0129
PST0130
PST0131
Message | Drive <number> is removed from disk drive bay <bay>. |
LCD Message | Drive <number> removed from disk drive bay <bay>. Check drive. |
Details | The controller detected that the drive was removed. |
Action | Verify drive installation. |
Message | Drive mismatch detected for drive <number> in disk drive bay <bay>. |
LCD Message | Drive mismatch detected for drive <number> in bay <bay>. Install correct drive type. |
Details | The installed disk does not meet the array requirements, for example a SATA disk may |
| not operate in an array containing SAS drives. |
Action | Verify that the disk meets the array requirements. |
Message | No memory is detected. |
LCD Message | No memory is detected. Inspect memory devices. |
Details | System BIOS was unable to detect memory in the system . |
Action | |
Message | Memory is detected, but is not configurable. |
LCD Message | Memory is detected, but is not configurable. Check memory devices. |
Details | System BIOS detected memory, but was unable to configure the memory for system |
| operation. |
Action | Compare system memory installation to supported system memory configurations. |
Message | Memory is configured, but not usable. |
LCD Message | Memory is configured, but not usable. Check memory devices |
Details | The system BIOS encountered device failures or speed configurations that resulted in |
| unused memory. |
Action | |
Message | System BIOS shadow failed. |
LCD Message | System BIOS shadow failed. Check memory devices. |
Details | Memory errors occurred copying BIOS image into system memory. |
102