Pelco C1927M operation manual Twice

Page 18

Table C. Operation Guide (Continued)

OPERATION

 

FRONT PANEL COMMAND

RESULT

 

 

 

 

 

 

Sequence PIP display.

1.

Push the

 

button.

Sequences all active cameras in

 

(Does not work in RECORD

2.

Push the SEQUENCE button.

the PIP display.

 

or VCR modes)

 

 

 

 

 

 

 

 

Stop a sequence.

Press the SEQUENCE button once or press any

Stops the sequence. The monitor

 

CAMERA button to stop a sequence on the main

displays video from the camera on

 

monitor. Press the SEQUENCE button twice to

which the sequence stops.

 

stop a sequence on the spot monitor.

 

 

 

 

 

Zoom on a camera.

1.

Press the CAMERA button for the camera on

Stops a sequence if one is in pro-

 

 

which you want to zoom.

gress. Displays a 2X or 4X zoom of

(Does not work in RECORD

 

 

 

 

the camera selected on the main

mode)

2.

Press the button below the ZOOM icon. The

monitor.

 

 

display will zoom to 2X magnification.

 

 

3.

Use the arrow buttons to control the zoom loca-

 

 

 

tion.

 

 

 

4.

Press the zoom button a second time to

 

 

 

increase the zoom to 4X.

 

 

5.

To exit, press the zoom button a third time.

 

 

 

 

Record a tape.

Recording is done automatically as long as a VCR

Records all cameras connected to

 

is connected and both the multiplexer and VCR

the multiplexer.

 

are in the RECORD mode. While the multiplexer

 

 

is in the RECORD mode (RECORD LED is on),

 

 

you can only see a full-screen view of one camera

 

 

(or one camera at a time if sequencing) on the

 

 

main monitor.

 

 

 

 

 

 

Play a tape.

1.

Make sure the RECORD LED on the left of the

Displays the recorded cameras in

 

 

front panel is OFF. If the light is not off, press

the selected format on the main

 

 

the DISPLAY/RECORD button until the monitor

monitor.

 

 

shows VCR mode.

 

 

2.

Turn on the VCR and press the PLAY button.

 

 

3.

Press the button of the camera you want to

 

 

 

view, or press a button below the 4, 9, or 16

 

 

 

icons for multiple camera playback.

 

 

 

 

 

Deactivate alarm(s) for

1.

For a single alarm, press the VIEW button once.

Deactivates the alarm.

camera displayed on the

 

 

 

 

 

main monitor

2.

For multiple alarms press the VIEW button

Deactivates the alarms.

 

 

once each time a camera with an alarm

 

 

 

sequences to the main monitor.

 

 

 

 

 

Deactivate alarm(s) for

1.

For a single alarm, press the VIEW button

Deactivates the alarm.

camera displayed on the

 

twice.

 

 

spot monitor.

 

 

 

 

 

 

2.

For multiple alarms, press the VIEW button

Deactivates the alarms.

 

 

twice each time a camera with an alarm

 

 

 

sequences to the spot monitor.

 

 

 

 

 

Open or close a log of the last

1.

Press the VIEW button twice to display the

Displays or removes alarm list on

20 alarms.

 

alarm list.

 

the main monitor.

 

2.

Press the VIEW button twice to clear the list

 

 

 

and close the log.

 

 

3.

Press any CAMERA or the VIEW button once

 

 

 

to close the log without clearing the alarm list.

 

 

 

 

 

 

 

18

Pelco Manual C1927M (5/99)

Image 18
Contents Listed Contents List of Illustrations List of TablesThis page intentionally left blank Pelco Manual C1927M 5/99 Important Safeguards and Warnings What is a Video MULTIPLEXER?Description Genex Series Simplex Multiplexers ApplicationsStand-Alone Multiplexer Models Color SimplexMonochrome Simplex Installation Basic Installation MountingCameras Cable Type Maximum DistanceRG6/U Monitors VCRPelco Time-Lapse VCR Wiring Example Pelco TIME-LAPSE VCRAlarms PELCO’S TIME-LAPSE VcrsPowering the Multiplexer Multiplexer with KBD4000 KeyboardOperation Multiplexer with MX4000SVR ServerButton Operation Function Operation Front Panel Command Result Spot Monitor DisplayTwice Password Menus System Setup View ButtonProgramming Title Display Time and DateTime Display Record SpeedsVanced Setup Advanced System Setup View ButtonAlarm Inputs Dwell RatesFront Panel Control PasswordDate Format Spot Monitor DisplayRecord Setup DISPLAY/RECORD Button Ntsc PAL Custom VCR Setup DISPLAY/RECORD Button URE Custom VCRInterval Video Termination Camera Setup Camera ButtonsAlarm Input Coaxitron FormatActivity Mask Setup Activity Dectection Mask Pelco Manual C1927M 5/99Sequence Setup Sequence Button Multiple Camera Display Setup Help MenuProgramming the PICTURE-IN-PICTURE Display Button Programming the 4-CAMERA Displays Button Programming the 9-CAMERA Displays ButtonProgramming the 16-CAMERA Display Button MM-DD-YY NTSC/EIA Programming Menu DefaultsMenu Default DD-MM-YY PAL/CCIRTroubleshooting Video SpecificationsReset ElectricalWarranty and Return Information Regulatory NoticesRevision History

C1927M specifications

The Pelco C1927M is a high-performance camera known for its advanced features and exceptional image quality. Designed for various surveillance applications, this camera blends robust construction with cutting-edge technology, making it a popular choice among security professionals worldwide.

One of the standout features of the C1927M is its high-resolution imaging capability. With a resolution of 1920x1080 pixels, it delivers clear and detailed images, making it suitable for environments where identifying individuals and capturing fine details is essential. The camera is equipped with a powerful image sensor that excels in both well-lit and low-light conditions, providing adaptability across different lighting scenarios.

The C1927M also incorporates advanced WDR (Wide Dynamic Range) technology, which helps to capture images in challenging lighting conditions. This feature is particularly beneficial in situations where bright light and shadows coexist, ensuring that both the dark and bright areas of a scene are well-defined. This capability allows for better video clarity during high-contrast scenarios, such as entrances or windows illuminated by sunlight.

In terms of connectivity, the Pelco C1927M supports various interfaces, including IP connectivity for seamless integration into existing network systems. This flexibility makes it compatible with various Video Management Systems (VMS), allowing for centralized monitoring and management of multiple cameras. The camera is designed with user-friendly features, including remote access capabilities, enabling users to view live feeds and recordings from anywhere, enhancing situational awareness and response times.

Additionally, the C1927M is built to withstand the rigors of outdoor environments. Its robust housing is rated for weather resistance, ensuring reliable operation in adverse conditions. With features such as PoE (Power over Ethernet), installation and maintenance become easier, reducing the clutter of additional power supplies and simplifying the setup process.

Another key characteristic of the Pelco C1927M is its integration of advanced analytics. These intelligent features enable enhanced motion detection, line crossing alerts, and tampering detection, improving overall security management. By leveraging these analytics, users can receive timely notifications and insights, allowing for proactive measures and incident management.

In summary, the Pelco C1927M stands out as a versatile, high-resolution surveillance camera designed to meet the demands of both commercial and industrial applications. With its advanced imaging capabilities, robust construction, and intelligent analytics, it offers a comprehensive solution for enhancing security and monitoring. Whether deployed in urban settings, retail environments, or broader public spaces, the C1927M reliably delivers high-quality video feeds while ensuring optimal performance in various operational contexts.