Pelco C1927M Programming the 4-CAMERA Displays Button, Programming the 9-CAMERA Displays Button

Page 30

NOTE: All active cameras may be sequenced in one location of a 4-, 9-, or 16- camera display mode. While in a multiple-camera display mode, use the arrow buttons to move the on-screen bar to the camera location for sequencing. Press the se- quence button to initiate sequencing of all active cameras. Refer to the Op- eration Guide table also.

PROGRAMMING THE 4-CAMERA DISPLAYS ( BUTTON)

You can program four groups of four cameras each. Each of the four groups can be

programmed to include any four cameras. is not available in RECORD mode.

To program the four-camera displays:

1.Press the button to call up a four-camera display. If necessary, press the button again to advance to the four-camera group that you wish to configure.

2.Press the button for approximately three seconds. A bar will appear in the first camera location of the four-camera display, indicating that you are in the programming mode.

3.Use the arrow buttons to move to each camera location in the four-camera display.

4.When the camera location that you desire is highlighted, choose the new camera by pressing the camera button for the desired camera.

5.To exit the programming mode, press any arrow button as many times as necessary until the bar moves off the screen.

6.If necessary, repeat steps 1-5 to program another group.

PROGRAMMING THE 9-CAMERA DISPLAYS ( BUTTON)

You can program two groups of nine cameras each. Both groups can be programmed to

include any nine cameras. is not available in RECORD mode.

To program the nine-camera displays:

1.Press the button to call up a nine-camera display. If necessary, press the button again to advance to the other nine-camera group.

2.Press the button for approximately three seconds. A bar will appear in the first camera location of the nine-camera display, indicating that you are in the programming mode.

3.Use the arrow buttons to move to each camera location in the nine-camera display.

4.When the camera location that you desire is highlighted, choose the new camera by pressing the camera button for the desired camera.

5.To exit the programming mode, press any arrow button as many times as necessary until the bar moves off the screen.

6.If necessary, repeat steps 1-5 to program the second group.

PROGRAMMING THE 16-CAMERA DISPLAY ( BUTTON)

is not available in RECORD mode.

To program the 16-camera display:

1.Press the button to call up the 16-camera display.

2.Press the button for approximately three seconds. A bar will appear in the first camera location of the 16-camera display, indicating that you are in the programming mode.

3.Use the arrow buttons to move to each camera location in the 16-camera display.

4.When the camera location that you desire is highlighted, choose the new camera by pressing the camera button for the desired camera.

5.To exit the programming mode, press any arrow button as many times as necessary until the bar moves off the screen.

30

Pelco Manual C1927M (5/99)

Image 30
Contents Listed Contents List of Illustrations List of TablesThis page intentionally left blank Pelco Manual C1927M 5/99 Important Safeguards and Warnings What is a Video MULTIPLEXER?Description Genex Series Simplex Multiplexers ApplicationsStand-Alone Multiplexer Models Color SimplexMonochrome Simplex Installation Basic Installation MountingCameras Cable Type Maximum DistanceRG6/U Monitors VCRPelco Time-Lapse VCR Wiring Example Pelco TIME-LAPSE VCRAlarms PELCO’S TIME-LAPSE VcrsPowering the Multiplexer Multiplexer with KBD4000 KeyboardOperation Multiplexer with MX4000SVR ServerButton Operation Function Operation Front Panel Command Result Spot Monitor DisplayTwice Password Menus System Setup View ButtonProgramming Title Display Time and DateTime Display Record SpeedsVanced Setup Advanced System Setup View ButtonAlarm Inputs Dwell RatesFront Panel Control PasswordDate Format Spot Monitor DisplayRecord Setup DISPLAY/RECORD Button Ntsc PAL Custom VCR Setup DISPLAY/RECORD Button URE Custom VCRInterval Video Termination Camera Setup Camera ButtonsAlarm Input Coaxitron FormatActivity Mask Setup Activity Dectection Mask Pelco Manual C1927M 5/99Sequence Setup Sequence Button Multiple Camera Display Setup Help MenuProgramming the PICTURE-IN-PICTURE Display Button Programming the 4-CAMERA Displays Button Programming the 9-CAMERA Displays ButtonProgramming the 16-CAMERA Display Button MM-DD-YY NTSC/EIA Programming Menu DefaultsMenu Default DD-MM-YY PAL/CCIRTroubleshooting Video SpecificationsReset ElectricalWarranty and Return Information Regulatory NoticesRevision History

C1927M specifications

The Pelco C1927M is a high-performance camera known for its advanced features and exceptional image quality. Designed for various surveillance applications, this camera blends robust construction with cutting-edge technology, making it a popular choice among security professionals worldwide.

One of the standout features of the C1927M is its high-resolution imaging capability. With a resolution of 1920x1080 pixels, it delivers clear and detailed images, making it suitable for environments where identifying individuals and capturing fine details is essential. The camera is equipped with a powerful image sensor that excels in both well-lit and low-light conditions, providing adaptability across different lighting scenarios.

The C1927M also incorporates advanced WDR (Wide Dynamic Range) technology, which helps to capture images in challenging lighting conditions. This feature is particularly beneficial in situations where bright light and shadows coexist, ensuring that both the dark and bright areas of a scene are well-defined. This capability allows for better video clarity during high-contrast scenarios, such as entrances or windows illuminated by sunlight.

In terms of connectivity, the Pelco C1927M supports various interfaces, including IP connectivity for seamless integration into existing network systems. This flexibility makes it compatible with various Video Management Systems (VMS), allowing for centralized monitoring and management of multiple cameras. The camera is designed with user-friendly features, including remote access capabilities, enabling users to view live feeds and recordings from anywhere, enhancing situational awareness and response times.

Additionally, the C1927M is built to withstand the rigors of outdoor environments. Its robust housing is rated for weather resistance, ensuring reliable operation in adverse conditions. With features such as PoE (Power over Ethernet), installation and maintenance become easier, reducing the clutter of additional power supplies and simplifying the setup process.

Another key characteristic of the Pelco C1927M is its integration of advanced analytics. These intelligent features enable enhanced motion detection, line crossing alerts, and tampering detection, improving overall security management. By leveraging these analytics, users can receive timely notifications and insights, allowing for proactive measures and incident management.

In summary, the Pelco C1927M stands out as a versatile, high-resolution surveillance camera designed to meet the demands of both commercial and industrial applications. With its advanced imaging capabilities, robust construction, and intelligent analytics, it offers a comprehensive solution for enhancing security and monitoring. Whether deployed in urban settings, retail environments, or broader public spaces, the C1927M reliably delivers high-quality video feeds while ensuring optimal performance in various operational contexts.