Multiquip GB2000 manual Transporting Safety,  Never lift the equipment while engine is running

Page 11

SAFETY INFORMATION

TRANSPORTING SAFETY

CAUTION

Before lifting, make sure that light tower parts are not damaged and screws are not loosened or lost.

ALWAYS make sure crane or lifting device has been properly secured to lifting hook of the equipment.

NEVER lift the equipment while engine is running.

Remove fan power cord from junction box before towing.

Make sure tower (mast) is in the stowed position and the GB2000 is removed from the mast before lifting.

REMOVE

STOWEDGB2000

POSITIONBEFORE

TRANSPORTING

MAST

LOCK

REMOVE

FAN

POWER

CORD

ALWAYS Make sure rear mast lock is secure before lifting.

Use adequate lifting cable (wire or rope) of suffi cient strength.

Use one point suspension hook and lift straight upwards.

LIFTING BALE

LIGHT TOWER

FORKLIFT

POCKETS

If lifting through pockets, make sure forks of forklift are inserted in pockets as far as possible before lifting.

Place chock blocks underneath wheel to prevent rolling while parked.

Place support blocks underneath the trailer’s bumper to prevent tipping while parked.

Use the trailer’s swivel jack to adjust the trailer height to a level position while parked.

NEVER allow any person or animal to stand underneath the equipment while lifting.

DO NOT lift equipment to unnecessary heights.

Loading and Tie-Down on Flatbed Truck

NOTICE

Before loading light tower to fl atbed truck, disconnect all connectors and tie-wrap the cables against the T-bar to prevent damage to the cables and connectors.

Remove and stow the GB2000 in a safe place where it will not get damaged before loading the light tower onto a fl atbed truck, towing, or shipping via a container.

When loading onto fl atbed truck, make sure that front jackstand of light tower is retracted and in the horizontal position so that the foot does not make contact with the

deck fl oor.

FRONT JACKSTAND

RETRACTED

TONGUE

TRANSPORT

 

 

TIE-DOWN

 

POINT (4)

SIDE

REAR

JACK

JACK

STAND (2)

STAND (2)

Make sure that the two side (left and right) and two rear jackstands are in the vertical postion, slightly extended, so that each foot makes contact with the deck fl oor.

Straps and chains should be routed through the transport tie-down points located beneath each corner of the cabinet to allow even application of force to the front and rear of the machine.

DO NOT secure the unit by running a strap or chain over the tongue of the light tower. This may cause severe damage to the unit.

GB2000 CSA BALLOON LIGHT• OPERATION AND PARTS MANUAL — REV. #1 (02/25/14)— PAGE 11

Image 11
Contents This Manual Must Accompany the Equipment AT ALL Times Model GB2000Page Page GB2000 Balloon Light Table of ContentsOrdering parts has never been easier Parts Ordering ProceduresSafety Messages Safety InformationGeneral Safety Lamp Safety Light Tower SafetyAny enclosed or narrow area Engine SafetyTowing Safety Light Tower Fuel Safety Never lift the equipment while engine is running Transporting Safety Never operate GB2000 in winds in excess of 40 MPH 64 km/h Electrical SafetyEnvironmental Safety Battery SafetySpecifications SpecificationsClosed Opened DimensionsFootcandle Plot Footcandle PlotGeneral Information GB2000 Components ComponentsMLT Light Tower SetupPower Disconnection PreparationRemove the adapter plate kit hardware from its container Lock Washer HEX NUT Lamp Mounting Balloon Power CableJunction BOX Mounting Lamp Bottom Lamp TOPLamp Cable Connections Lamp Lighting OptionsGB2000 Lamp Lamp Lamp Option 6 Lighting Configuration Inflating Balloon and Turning on Lamps LT12 only OperationRemoving Balloon Protective Cover Deflating and Storing Balloon Inflating Balloon and Turning on Lamps MLT onlyReplacing Lamp MaintenanceReplacing Balloon Replacing BalloonSymptom Possible Problem Solution Wiring Diagram Xxxxx only Not Used on Sample Parts ListExplanation of Code in Remarks Column Filter Suggested Spare PartsLamp UR N Hazar D Nameplate and DecalsDecal CAUTION, AC only Decal WARNING, Burn Hazard EnglishDecal WARNING, Burn Hazard French Decal CAUTION, Lamp TypeElectrical Assy Lamp Guard Micro SwitchMicro Switch Cover Micro Switch CAPElectrical Assy PIN FAN Power SourceRelay Assy FlangeBracket and J-BOX Assy Adapter CP BOX RelayRubber CAP CAP NUT M4Freight Policy Terms and Conditions of Sale PartsPage HERE’S HOW to GET Help
Related manuals
Manual 52 pages 8.66 Kb

GB2000 specifications

The Multiquip GB2000 is a cutting-edge generator designed to meet the needs of a variety of industries, offering reliable and efficient power solutions. Built with advanced technology and user-friendly features, the GB2000 is tailored for both professionals and contractors who require consistent performance in demanding environments.

One of the standout characteristics of the GB2000 is its robust engine, which is engineered for high efficiency and low emissions. This generator is powered by a high-performance engine that provides a substantial power output, ensuring that it can support a wide range of devices and tools. The emphasis on performance makes it suitable for construction sites, events, and emergency backup applications.

The GB2000 also boasts a compact and durable design, making it easy to transport and store. Its lightweight frame does not compromise on durability, as it is built from high-quality materials that can withstand the rigors of daily use. This portability is enhanced by built-in handles and a well-balanced structure, allowing users to maneuver it effortlessly in various settings.

Another significant feature of the GB2000 is its digital control panel, which provides real-time information about power output, fuel levels, and operational status. This intuitive control interface simplifies operation and enhances user experience, allowing users to monitor their power needs effectively and make quick adjustments as necessary.

In terms of safety, the Multiquip GB2000 incorporates several protective measures. This includes automatic low oil shutdown, circuit breaker protection, and a robust frame that protects the engine from external impacts. These features ensure the longevity of the generator while also providing peace of mind to users in high-demand situations.

Technologically, the GB2000 utilizes an advanced inverter system that delivers clean and stable power, crucial for sensitive electronic devices. This inverter technology not only improves fuel efficiency but also minimizes noise production, making it ideal for use in environments where sound levels are a concern.

Overall, the Multiquip GB2000 combines power, portability, and advanced technology, making it a top contender in the portable generator market. Its user-friendly design, safety features, and robust performance ensure it meets the diverse requirements of modern power users, establishing it as a reliable choice for both everyday and emergency power needs.