Multiquip GB2000 manual Light Tower Safety, Lamp Safety

Page 8

SAFETY INFORMATION

LIGHT TOWER SAFETY

DANGER

NEVER operate the equipment in an explosive atmosphere or near combustible materials.An explosion or fi re could result causing severe bodily harm or even death.

WARNING

NEVER disconnect any emergency or safety devices. These devices are intended for operator safety. Disconnection of these devices can cause severe injury, bodily harm or even death. Disconnection of any of these devices will void all warranties.

CAUTION

NEVER lubricate components or attempt service on a running machine.

ALWAYS ensure light tower is on level ground before use so that it cannot slide or shift around, endangering workers. Always keep immediate area free of bystanders.

ALWAYS make sure trailer is leveled with all outriggers extended before raising tower. Outriggers must remain extended while tower is up.

ALWAYS keep area behind trailer clear of people while raising and lowering mast.

NEVER remove safety pin or pull mast locking pin while tower is in a raised position!

CHECK the mast and winch cables for wear. If any problem occurs when lowering or raising the tower, STOP immediately! Contact a trained technician for assistance.

NEVER pivot or retract mast while unit is operating.

NEVER use the light tower mast as a crane. DO NOT lift anything with the mast.

ALWAYS lower the light tower when not in use, or if high winds or electrical storms are expected.

NOTICE

ALWAYS keep the immediate area surrounding the light tower clean, neat, and free of debris.

ALWAYS keep the machine in proper running condition.

Fix damage to machine and replace any broken parts immediately.

ALWAYS store equipment properly when it is not being used. Equipment should be stored in a clean, dry location out of the reach of children and unauthorized personnel.

To prevent the light tower from overturning, NEVER use in winds that exceed 65 MPH (105 km/h).

LAMP SAFETY

WARNING

NEVER attempt to replace lamp with the power on. Always shut down the engine and turn off circuit breakers when changing the lamp.

ALWAYS allow a suffi cient amount of time for the lamp to cool before touching or changing. The possibility exists of severe burns.

CAUTION

NEVER use force when installing the lamp.Excessive force could cause the lamp to break, causing bodily harm.

NOTICE

NEVER leave any grease or oil residue on lamp surface when replacing or removing lamp. This can create hot spots, reducing the service life of the lamp.

ALWAYS make sure lamp surface is clean and dry.

ALWAYS replace with MQ recommended type lamp.

ALWAYS have a trained technician install and remove a fl oodlight, or replace any damaged fi xture wiring.

PAGE 8 —GB2000 BALLOON LIGHT• OPERATION AND PARTS MANUAL — REV. #1 (02/25/14)

Image 8
Contents Model GB2000 This Manual Must Accompany the Equipment AT ALL TimesPage Page Table of Contents GB2000 Balloon LightParts Ordering Procedures Ordering parts has never been easierSafety Information Safety MessagesGeneral Safety Light Tower Safety Lamp SafetyEngine Safety Any enclosed or narrow areaFuel Safety Towing Safety Light TowerTransporting Safety  Never lift the equipment while engine is runningElectrical Safety  Never operate GB2000 in winds in excess of 40 MPH 64 km/hBattery Safety Environmental SafetySpecifications SpecificationsDimensions Closed OpenedFootcandle Plot Footcandle PlotGeneral Information Components GB2000 ComponentsSetup Power DisconnectionPreparation MLT Light TowerRemove the adapter plate kit hardware from its container Lock Washer HEX NUT Lamp Mounting Balloon Power CableJunction BOX Mounting Lamp TOP Lamp BottomLamp Lighting Options Lamp Cable ConnectionsGB2000 Lamp Lamp Lamp Option 6 Lighting Configuration Inflating Balloon and Turning on Lamps LT12 only OperationRemoving Balloon Protective Cover Inflating Balloon and Turning on Lamps MLT only Deflating and Storing BalloonMaintenance Replacing LampReplacing Balloon Replacing BalloonSymptom Possible Problem Solution Wiring Diagram Xxxxx only Not Used on Sample Parts ListExplanation of Code in Remarks Column Filter Suggested Spare PartsLamp Nameplate and Decals UR N Hazar DDecal WARNING, Burn Hazard English Decal WARNING, Burn Hazard FrenchDecal CAUTION, Lamp Type Decal CAUTION, AC onlyElectrical Assy Micro Switch Micro Switch CoverMicro Switch CAP Lamp GuardElectrical Assy FAN Power Source Relay AssyFlange PINBracket and J-BOX Assy BOX Relay Rubber CAPCAP NUT M4 Adapter CPTerms and Conditions of Sale Parts Freight PolicyPage HERE’S HOW to GET Help
Related manuals
Manual 52 pages 8.66 Kb

GB2000 specifications

The Multiquip GB2000 is a cutting-edge generator designed to meet the needs of a variety of industries, offering reliable and efficient power solutions. Built with advanced technology and user-friendly features, the GB2000 is tailored for both professionals and contractors who require consistent performance in demanding environments.

One of the standout characteristics of the GB2000 is its robust engine, which is engineered for high efficiency and low emissions. This generator is powered by a high-performance engine that provides a substantial power output, ensuring that it can support a wide range of devices and tools. The emphasis on performance makes it suitable for construction sites, events, and emergency backup applications.

The GB2000 also boasts a compact and durable design, making it easy to transport and store. Its lightweight frame does not compromise on durability, as it is built from high-quality materials that can withstand the rigors of daily use. This portability is enhanced by built-in handles and a well-balanced structure, allowing users to maneuver it effortlessly in various settings.

Another significant feature of the GB2000 is its digital control panel, which provides real-time information about power output, fuel levels, and operational status. This intuitive control interface simplifies operation and enhances user experience, allowing users to monitor their power needs effectively and make quick adjustments as necessary.

In terms of safety, the Multiquip GB2000 incorporates several protective measures. This includes automatic low oil shutdown, circuit breaker protection, and a robust frame that protects the engine from external impacts. These features ensure the longevity of the generator while also providing peace of mind to users in high-demand situations.

Technologically, the GB2000 utilizes an advanced inverter system that delivers clean and stable power, crucial for sensitive electronic devices. This inverter technology not only improves fuel efficiency but also minimizes noise production, making it ideal for use in environments where sound levels are a concern.

Overall, the Multiquip GB2000 combines power, portability, and advanced technology, making it a top contender in the portable generator market. Its user-friendly design, safety features, and robust performance ensure it meets the diverse requirements of modern power users, establishing it as a reliable choice for both everyday and emergency power needs.