CONNECTING ANALOG CAMERAS
DX4708/DX4808 units support up to eight analog cameras and two IP cameras. DX4716/DX4816 units support up to sixteen analog and two IP cameras. Be sure to disconnect power from each camera before connecting it to the unit. Also, use
Table A. Video Coaxial Cable Requirements
Cable Type* | Maximum Distance |
|
|
RG59/U | 229 m (750 ft) |
|
|
RG6/U | 305 m (1,000 ft) |
|
|
RG11/U | 457 m (1,500 ft) |
|
|
*Cable requirements:
NOTE: Operational issues may occur when analog cameras are not correctly terminated. When connecting camera devices, use a normal termination of 75 ohms. When using the video
CONNECTING IP CAMERAS
The DX4700/DX4800 supports up to two IP cameras. For information about the supported IP camera resolutions, refer to Appendix D: Supported IP Camera Resolutions in the DX4700/DX4800 Series Server Operation/Configuration manual.
NOTES:
•The unit does not support alarm or motion recording for IP cameras.
•IP cameras only record in the normal recording mode.
•The IP camera video stream must be configured as recommended by Pelco (refer to Figure 6).
Figure 6. Recommended IP Camera Settings
16 | C4675M (2/11) |