Pelco DX4700 manual Connecting Analog Cameras, Connecting IP Cameras, Cable Type Maximum Distance

Page 16

CONNECTING ANALOG CAMERAS

DX4708/DX4808 units support up to eight analog cameras and two IP cameras. DX4716/DX4816 units support up to sixteen analog and two IP cameras. Be sure to disconnect power from each camera before connecting it to the unit. Also, use 75-ohm video coaxial cables with BNC connectors to connect the analog cameras to the unit. Refer to Table A for coaxial cable requirements.

Table A. Video Coaxial Cable Requirements

Cable Type*

Maximum Distance

 

 

RG59/U

229 m (750 ft)

 

 

RG6/U

305 m (1,000 ft)

 

 

RG11/U

457 m (1,500 ft)

 

 

*Cable requirements: 75-ohms impedance All-copper center conductor

All-copper braided shield with 95% braid coverage.

NOTE: Operational issues may occur when analog cameras are not correctly terminated. When connecting camera devices, use a normal termination of 75 ohms. When using the video loop-through option, make sure the signal is terminated at the last device. For additional information about terminating a specific device, refer to the device’s installation manual.

CONNECTING IP CAMERAS

The DX4700/DX4800 supports up to two IP cameras. For information about the supported IP camera resolutions, refer to Appendix D: Supported IP Camera Resolutions in the DX4700/DX4800 Series Server Operation/Configuration manual.

NOTES:

The unit does not support alarm or motion recording for IP cameras.

IP cameras only record in the normal recording mode.

The IP camera video stream must be configured as recommended by Pelco (refer to Figure 6).

Figure 6. Recommended IP Camera Settings

16

C4675M (2/11)

Image 16
Contents DX4700/DX4800 Series Hybrid Video Recorder Contents List of Illustrations List of TablesImportant Notices Legal NoticeRegulatory Notices Video Quality CautionOpen Source Software Notice Description Client Application SoftwareOptional Accessories ModelsPackage Contents Product OverviewFront Panel System Status IndicatorsChannel and Camera Control Buttons Playback Controls Selection ControlShuttle Dial outer ring Monitor Selection VGA Monitor Output 15-pin output Rear PanelEthernet Adapter Port 100 Mbps port Remote Control PTZ Controls~é Playback Controls ~ã Menu ControlsLens Controls Equipment Placement InstallationEquipment Connections Overview Connecting IP Cameras Connecting Analog CamerasCable Type Maximum Distance Connecting Serial PTZ Protocol Name ManufacturerConnecting Alarm Devices Connecting Alarm DevicesConnecting the Main Monitor Connecting a Relay OutputConnecting the Spot Monitor Connecting USB Devices Connecting Audio DevicesConnecting the Mouse Connecting to a NetworkInstalling Client Software Memory 256 MB Video 64 MBUnit Startup Operation/ConfigurationLogging on and Logging OFF Unit Shutdown Specifications VideoAppendix a Connecting ATM/POS Devices AppendixesAppendix B Connecting Audio Devices Product Warranty and Return Information